发布采购

SDS60UT00 参数 Datasheet PDF下载

SDS60UT00图片预览
型号: SDS60UT00
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用: 电源电路
文件页数/大小: 2 页 / 172 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号SDS60UT00的Datasheet PDF文件第2页  
AC-DC
60 Watts
SDS60 Series
xppower.com
Single, Dual, Triple & Quad Outputs
Output Voltages from 3.3 V to 48 V
Non-standard Outputs Available
Universal AC Input
Low Profile - 1.2” (30.5 mm)
Fits 1U Applications
Up to 88% Efficiency
Specification
Input
Input Voltage
Input Frequency
Input Current
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 1.6 A at 115 VAC
1.0 A at 230 VAC
Inrush Current
• <15 A at 115 VAC
<30 A at 230 VAC
Earth Leakage Current
• <0.30 mA at 115 VAC
<0.75 mA at 230 VAC
Input Protection
• 2 A/250 VAC internal fuse
General
Efficiency
Isolation
• 80% typ, 88% max, 230 VAC 100% load
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 60 kHz typical
• 3.5 W/In
3
• Green DC OK LED
• >100 kHrs per MIL-HDBK-217F
Switching Frequency
Power Density
Signals
MTBF
Environmental
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
• See table
• ±10% on V1 only (see note 4)
• Single output models: ±1%
Multi-output models: ±5%
Minimum Load
• 10% required on V1 & V2 of multi-output
models to maintain regulation, unit will
start up with no load
Start Up Delay
• 1 s typical
Hold Up Time
• 12 ms min at 110 VAC, 100% load
Line Regulation
• 1% from low line to high line
Load Regulation
• 5% max all models, ±10% with no load
on V1 - see table
Transient Response
• 4% max deviation, recovery to within
1% in 4 ms for a 50% load change
Ripple & Noise
• 1% pk-pk typical, 20 MHz BW
Overvoltage Protection
• 112-132%, recycle input to reset
Overload Protection
• All outputs 110-150% with auto recovery
Short Circuit Protection
• Trip & restart (Hiccup mode),
auto recovery
Temperature
• 0.04%/°C
Coefficient
Operating Temperature
• 0 °C to +70 °C, derate linearly from 100%
load at +40 °C to 50% load at +70 °C
Cooling
• Convection-cooled
Operating Humidity
• 5-95% RH, non-condensing
Storage Temperature
• -40 °C to +85 °C
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
EN55022, FCC Part 15, level B conducted
EN61000-3-2
EN61000-3-3
EN61000-4-2, level 2 Perf Criteria A
EN61000-4-3, 3 V/m Perf Criteria A
EN61000-4-4, level 2 Perf Criteria A
EN61000-4-5, level 3 Perf Criteria A
EN61000-4-6, 3 V Perf Criteria A
EN61000-4-8, 1 A/m Perf Criteria A
EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950-1, UL60950-1,
CSA60950-1 per cUL, CE Mark LVD
Safety Approvals