欢迎访问ic37.com |
会员登录 免费注册
发布采购

SMQ400PS12-C 参数 Datasheet PDF下载

SMQ400PS12-C图片预览
型号: SMQ400PS12-C
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用: 电源电路
文件页数/大小: 2 页 / 212 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号SMQ400PS12-C的Datasheet PDF文件第2页  
AC-DC
300/400 Watts
SMQ Series
High Power Density
High Peak Load Rating
DC OK
Remote On/Off
Universal Input
xppower.com
Single Outputs from 12.0 V to 54.0 V
Internal Fan
Specification
Input
Input Voltage
Input Frequency
Input Current
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 5.00 A at 90 VAC (SMQ300),
6.35 A at 90 VAC (SMQ400)
Inrush Current
• 35 A max at 230 VAC
Power Factor
• 0.99 typical
Earth Leakage Current
• <2.5 mA at 230 VAC/50Hz
<1.5 mA at 115 VAC/60Hz
General
Efficiency
Isolation
• 80% typical
• 3000 VAC Input to Output,
1500 VAC Input to Ground,
250 VDC Output to Ground
• 60 kHz typical for PFC stage,
30 kHz typical for main converter
• 4.7 W/In
3
(SMQ300), 6.25 W/In
3
(SMQ400)
• DC OK, TTL HIGH within 100-500 ms
LOW 1 ms before loss of regulation
• 138 kHrs per MIL-HDBK-217F
Switching Frequency
Power Density
Signals
MTBF
Output
Output Voltage
Output Voltage Trim
Minimum Load
Start Up Delay
Hold Up Time
Line Regulation
Load Regulation
Transient Response
12 to 54 VDC - see table
See table
No minimum load required
2.5 s typical at 120 VAC
20 ms minimum at 120 VAC & 80% load
±1%
±1%
5% max. deviation, recovery to within
1% in 500 µs for a 50% load change
1% pk-pk, 20 MHz BW
115-130% Vnom, recycle input to reset
120-150% of nominal current,
auto recovery
Unit shuts down, auto recovery
Environmental
Operating Temperature
• 0 ˚C to +70 ˚C, derate linearly from
100% at +50 ˚C to 50% at +70 ˚C
Cooling
• Via internal fan
Operating Humidity
• 5-90% RH, non-condensing
Storage Temperature
• -20 ˚C to +85 ˚C
Shock
• 15 g (non-operation), 11 ms half
sine-wave, 3 times for each axis
Vibration
• 10 Hz - 55 Hz (non-operation) 2 g,
sweep time 3 mins, 60 mins/axis
Ripple & Noise
Overvoltage Protection
Overcurrent Protection
Overtemperature
Protection
Remote Sense
Remote On/Off
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022 and FCC Part 15,
level B conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 2 contact, level 3 air,
Perf Criteria A
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, level 3, Perf Criteria A
• EN61000-4-6, level 2, Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
• UL60950, CSA C22.2 No.60950,
EN60950, CE Mark LVD
• Compensates for up to 0.5 V drop
• On = TTL Logic High or Open circuit
Off = TTL Logic Low or Short circuit