Product specification
13
14
Surface-Mount Ceramic Multilayer Capacitors
General Purpose & High Cap.
Y5V
6.3 V to 50 V
TEST
Endurance
TEST METHOD
IEC 60384-
21/22
4.14
PROCEDURE
1.
Preconditioning, class 2 only:
REQUIREMENTS
No visual damage
<General purpose series>
∆C/C
Class2:
Y5V: ±30%
D.F.
Class2:
Y5V:
≤
15%
R
ins
Class2:
Y5V:
≥
1,000 MΩ or R
ins
x C
r
≥
50s
whichever is less
<High Capacitance series>
∆C/C
Class 2:
Y5V: ±30%
D.F.
Class 2:
Y5V: 2 x initial value max
R
ins
Class 2:
Y5V: 1,000 MΩ or R
ins
x C
r
≥
50s
whichever is less
150 +0/-10 °C /1 hour, then keep for
24 ±1 hour at room temp
2.
Initial measure:
Spec: refer initial spec C, D, IR
3.
Endurance test:
Temperature: Y5V: 85 °C
Specified stress voltage applied for 1,000 hours:
Applied 2.0 x U
r
for general product.
Applied 1.5 x U
r
for high cap. product.
4.
Recovery time: 24 ±2 hours
5.
Final measure: C, D, IR
P.S. If the capacitance value is less than the minimum
value permitted, then after the other measurements
have been made the capacitor shall be precondition
according to
“IEC 60384 4.1”
and then the
requirement shall be met.
Voltage proof
IEC 60384-1 4.6
Specified stress voltage applied for 1 minute
U
r
≤
100 V: series applied 2.5 U
r
100 V < U
r
≤
200 V series applied (1.5 U
r
+ 100)
200 V < U
r
≤
500 V series applied (1.3 U
r
+ 100)
U
r
> 500 V: 1.3 U
r
I: 7.5 mA
No breakdown or flashover
www.yageo.com
Jul 29, 2010 V.5