欢迎访问ic37.com |
会员登录 免费注册
发布采购

YAC523 参数 Datasheet PDF下载

YAC523图片预览
型号: YAC523
PDF下载: 下载PDF文件 查看货源
内容描述: 电动可变电阻2 [Electric Variable Resistance 2]
分类和应用:
文件页数/大小: 16 页 / 393 K
品牌: YAMAHA [ YAMAHA CORPORATION ]
 浏览型号YAC523的Datasheet PDF文件第3页浏览型号YAC523的Datasheet PDF文件第4页浏览型号YAC523的Datasheet PDF文件第5页浏览型号YAC523的Datasheet PDF文件第6页浏览型号YAC523的Datasheet PDF文件第8页浏览型号YAC523的Datasheet PDF文件第9页浏览型号YAC523的Datasheet PDF文件第10页浏览型号YAC523的Datasheet PDF文件第11页  
YAC523
・Volume
setting
The relationship between input code and volume value is as shown in the following table.
Input code
11111111
11111110
Gain or attenuate(dB)
MUTE
+31.5
11011111
+16.0
10111111
0
00000010
00000001
00000000
-94.5
-95.0
MUTE
The input codes ALL"0" and ALL"1" are set for mute.
・Zero-cross
mode
YAC523 incorporates the zero-cross detection function to suppress audible noise when the volume is changed
quickly. A mode is selected from the following four modes by setting ZCEN1 and 2 pins.
ZCEN[2:1]
00
01
10
11
Normal
Zero-cross mode A
Zero-cross mode B
Zero-cross mode C
Mode
Operation
Zero-cross is not detected, and the volume value is changed
immediately after the rising of CSN.
Zero-cross is detected after the rising of CSN, or after t
TM1
(20ms)
passes, volume value is changed.
Zero-cross is detected after the rising of CSN, or after t
TM2
(10ms)
passes, volume value is changed.
When the next data is written within t
TM1
(20ms) for zero-cross mode
A, the changed is performed at the falling of CSN by using the volume
value immediately before.
No zero-cross
No zero-cross
t < t
TM
&
t < t
TM
&
No zero-cross
t < t
TM
&
No zero-cross
t < t
TM
&
t
t
TM
CSN
SDATAI
Volumevalue
(Zero-cross
modeA,B)
Volumevalue
(Zero-cross
modeC)
-12dB
-9dB
-6dB
-15dB(Lastvalue)
-3dB
0dB
0dB
-15dB(Lastvalue)
-12dB
-9dB
-6dB
-3dB
0dB
Operation in each zero-cross mode when zero-cross is not detected
※Be
careful not to change the zero-cross mode during the operation of the device, or an erroneous operation
may be caused. Perform change of zero-cross mode after the elapse of 1 second or more from the rising of
CSN signal.
・Power
on reset
YAC523 builds in the power on reset function that resets the volume value when the power is turned on. Since
a system that perform the reset by detecting the power supply voltage level, when turning on the power supply
again, do it after the power supply voltage AVDD and AVSS has reduced sufficiently (to +1.0V/ -1.0V or less).
Moreover, although a volume register is reset at the time of a power supply injection, since shocking sound
occurs in the case of power supply ON/OFF, please apply mute to the whole set.
Power on reset is started when AVSS is 90%. At the time, AVDD should rise +1V or more. Since power-on
reset may be unable to be completed when conditions cannot be fulfilled, please perform a re-setup of a volume
register before canceling MUTE by the side of a set.
7