YB1300
Regulated Charge Pump 5V 100mA
Absolute Maximum Ratings
Supply Voltage......................................................5.5V
Output Voltage ......................................................5.5V
Output Short-Circuit Duration ....................Continuous
Junction Temperature Range........................... +125℃
Storage Temperature Range ............. -65℃ to +150℃
Lead Temperature............................................ +250℃
Recommended Operating
Conditions
Input Supply Voltage................................... 2V to 5V
Operating Temperature..................... -40℃ to +85℃
Electrical Characteristics
At T
A
=25℃, V
IN
=3.2V, I
OUT
=10mA, C
IN
=C
OUT
=2.2µF, C
PUMP
=0.22µF, V
ENABLE
=V
IN
, unless otherwise noted.
Table 2
Symbol
V
IN
V
OUT
I
OUT
I
SC
F
OSC
η
V
R
V
IH
V
IL
T
ST
T
RT
I
QC
I
SD
Note:
Function Parameter
Input Voltage
Output Voltage
Output Current
Output Current (short-circuit)
Oscillator Frequency
Efficiency
Ripple Voltage
Enable Control (High)
Enable Control (Low)
Thermal Shutdown
Thermal Recovery
Supply Current (Quiescent)
Supply Current (Shutdown)
Test Conditions
Min
2.7
Typ
Max
5.0
Units
V
V
V
mA
mA
MHz
%
mVpp
2.7V≦V
IN
<3.2V,
I
OUT
≦30mA
3.2V≦V
IN
<5V,
I
OUT
≦100mA
V
IN
=3V
V
IN
=3.2V
4.7
4.7
5.0
5.0
100
210
1
5.3
5.3
I
OUT
=20mA, V
IN
=2.7V
V
IN
=3.0V, I
OUT
=100mA
Vin=3.3V to 5.0V
Vin=3.3V to 5.0V
Shutdown Temperature
Recovery Temperature
I
OUT
=0mA
V
IN
=2.7-5.0V, Enable=0V
3
-0.2
88
50
V
IN
0.4
~160
~140
~30
~0.0
1
V
V
℃
℃
µA
µA
YB1300 MRev.1.2
WWW.YOBON.COM.TW
3