RELIABILITY DATA
1/1
SPARK GAPS
Item
Specified Value
Test Methods and Remarks
1.Operating Temperature
Range
K30CVJ85C
2.Operating Humidity Range
95%RH max.
fNo
dew condensationg
3.Storage Temperature
 Range
4.Discharge Voltage
K40CVJ85C
Within the specified tolerance
With Circuit 1 shown below, conduct measurement
with voltage application.
5.Insulation Resistance
10,000 ME min.
Applied voltageD500VDCfAG10、AG15、AG20g
1000VDCfAG40g
DurationDWithin 20 sec.
7
SURGE ABSORBERS
6.Capacitance
1pFmax.
Measuring frequencyD1M0.1MHz
Measuring voltageD0.5V5.0Vrms
Bias applicationDNone
7.Discharge
 Life
Discharge
Voltage
Change
Insulation
Resistance
8.Damp Heat
Discharge
Voltage
Change
Insulation
Resistance
9.Terminal
 Strength
Tensile
No damage
1000ME
5000ME
J70
K30
L
J50
K30
L
J70
K30
L
J20
K35
L
AG10
AG15、AG20、AG40
With the Circuit 2 shown below, repeat discharge
with specified voltage, followed by the measurement
within 2 to 5 hrs.
Number of dischargeD10,000 times
fAG10、AG15、AG20g
1000ME
5000ME
    D
5,000 timesfAG40g
TemperatureD40M2C
HumidityD90V95LRH
DurationD250 hrs
RecoveryD2 to 5 hrs of recovery under the standard
condition after the removal from test chamber.
Apply the tensile force in the direction to draw terminal.
Applied forceD9.8NfAG10、AG15、AG20g
D39.2NfAG40g
No damage
Torsional
Apply the bending force to incline the body to right and left
through angle of 90°
Applied forceD4.9NfAG10、AG15、AG20g
D9.8NfAG40g
Circuit 1
Circuit 2
  
AG10、AG15、AG20
  
RD20ME、
  
CD2000pF、
AG40
5ME
3000pF
AG10、
  
RD 20ME、
  
CD 3000pF、
AG15、AG20
20ME、
10000pF、
AG40
5ME
3000pF
  
ED Refer to individual specification
Note on standard condition: "standard condition" referred to herein is defined as follows:
5 to 35C of temperature, 45 to 85% relative humidity and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20M2C
of temperature, 60 to 70% relative humidity and 86 to 106kPa of air pressure.
Unless otherwise specified, all the tests are conducted under the "standard condition."
455