PHE840M
• EMI suppressor, class X2, metallized polypropylene
• 0.01 – 10.0 µF, 275/280 VAC, +105°C
• New, small dimensions including low profile capacitors
• Replaces PHE843
L
B
TYPICAL APPLICATIONS
For worldwide use as electromagnetic
interference suppressor in all X2 and
across-the-line applications.
CONSTRUCTION
Metallized polypropylene film encapsulated
with selfextinguishing epoxy resin in a box of
material recognized to UL 94 V–0.
0.5
p
∅
d
b
H
TECHNICAL DATA
Rated voltage
275 VAC 50/60 Hz (ENEC)
280 VAC 50/60 Hz (UL, CSA)
0.01 – 10.0 µF
± 20% standard, ± 10% option, ± 5% on request
–55 to +105°C
55/105/56/B
ENEC, UL, CSA
Maximum values at +23°C
C
≤
0.1 µF 0.1µF < C
≤
1 µF
1 kHz
0.1%
0.1%
10 kHz
0.2%
0.4%
100 kHz
0.6%
–
The 100% screening factory test is carried
out at 2200 VDC. The voltage level is
selected to meet the requirements in
applicable equipment standards. All
electrical characteristics are checked
after the test.
C
≤
0.33 µF:
≥
30 000 MΩ
C > 0.33 µF:
≥
10 000 s
Maximum voltage 630 VDC
p
l
Capacitance range
Capacitance tolerance
Temperature range
Climatic category
Approvals
Dissipation factor
d
0.4
0.4
0.4
0.4
0.4
0.5
0.6
0.6
0.8
0.8
0.8
1.0
std l
17
17
17
6
6
6
max l
20
30
30
30
30
30
b
±0.4
±0.4
±0.4
±0.4
±0.4
±0.7
7.5 ±
10.0 ±
15.0 ±
22.5 ±
27.5 ±
37.5 ±
C > 1 µF
0.1%
0.8%
–
Tolerance in lead length
< 30 mm
+0
mm
–1
≥
30 mm
+5
–0
mm
Test voltage between
terminals
Insulation resistance
In DC applications
ENVIRONMENTAL TEST DATA
Endurance
IEC 60384–14
1.25 x U
R
VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
3 directions at 2 hours each,
10–55 Hz at 0.75 mm or 98 m/s
2
1000 bumps at
390 m/s
2
Upper and lower rated
temperature 5 cycles
No visible damage
No open or short circuit
No visible damage
No open or short circuit
No visible damage
Vibration
IEC 60068–2–6
Test Fc
IEC 60068–2–29
Test Eb
Bump
Change of temperature
IEC 60068–2–14
Test Na
Active flammability
Passive flammability
EN 132400
IEC 60384-14 (1993)
EN 132400
UL1414
IEC 60068-2-3
Test Ca
Enclosure material of
UL94V–0 flammability class
Humidity
+40°C and
90 – 95% R.H.
56 days
144