内容描述: 155 Mb / s的SMF ( 15公里) 1X9 3.3V收发器的自动取款机。 SONET OC- 3 -40°C至+ 85°C蓝案例\n [155 Mb/s SMF (15km) 1x9 3.3V Transceiver for ATM. SONET OC-3 -40C to +85C Blue Case ]
分类和应用: 异步传输模式ATM
文件页数/大小: 10 页 / 209 K
品牌: ETC [ ETC ]
 浏览型号HFCT-5805C的Datasheet PDF文件第2页浏览型号HFCT-5805C的Datasheet PDF文件第3页浏览型号HFCT-5805C的Datasheet PDF文件第4页浏览型号HFCT-5805C的Datasheet PDF文件第5页浏览型号HFCT-5805C的Datasheet PDF文件第7页浏览型号HFCT-5805C的Datasheet PDF文件第8页浏览型号HFCT-5805C的Datasheet PDF文件第9页浏览型号HFCT-5805C的Datasheet PDF文件第10页  
Regulatory Compliance
The HFCT-5805 is intended to
enable commercial system
designers to develop equipment
that complies with the various
regulations governing
certification of Information
Technology Equipment. See the
Regulatory Compliance Table 1
for details. Additional
information is available from
your Agilent sales representative.
Electrostatic Discharge (ESD)
There are two design cases in
which immunity to ESD damage
is important.
The first case is during handling
of the transceiver prior to
mounting it on the circuit board.
It is important to use normal
ESD handling precautions for
ESD sensitive devices. These
precautions include using
grounded wrist straps, work
benches and floor mats in ESD
controlled areas.
The second case to consider is
static discharges to the exterior
of the equipment chassis
containing the transceiver parts.
To the extent that the duplex SC
connector is exposed to the
outside of the equipment chassis
it may be subject to whatever ESD
system level test criteria that the
equipment is intended to meet.
Electromagnetic Interference (EMI)
Most equipment designs utilizing
these high-speed transceivers
from Agilent will be required to
meet the requirements of FCC in
the United States, CENELEC
EN55022 (CISPR 22) in Europe
and VCCI in Japan.
The HFCT-5805 has been
characterized without a chassis
enclosure to demonstrate the
robustness of the part’s integral
shielding. Performance of a
system containing these
transceivers within a well
designed chassis is expected to
be better than the results of these
tests with no chassis enclosure.
Immunity
Equipment utilizing these
HFCT-5805 transceivers will be
subject to radio-frequency
electromagnetic fields in some
environments. These transceivers,
with their integral shields, have
been characterized without the
benefit of a normal equipment
chassis enclosure and the results
are reported below. Performance
of a system containing these
transceivers within a well
designed chassis is expected to
be better than the results of these
tests without a chassis enclosure.
Table 1. Regulatory Compliance - Typical Performance
Feature
Electrostatic Discharge
ESD) to the Electrical Pins
Electrostatic Discharge
ESD) to the Duplex SC
Receptacle
Electromagnetic
Interference (EMI)
Test Method
MII-STD-883C
Method 3015.4
Variation of
IEC 61000-4-2
FCC Class B
Performance
Class 1 (>500 V) - Human Body Model
Air discharge 15 kV
Immunity
Variation of IEC 801-3
Eye Safety
FDA CDRH 21-CFR 1040
Class 1
IEC 60825 - 1
Amendment 2 2001 - 01
Typically provide greater than 11 dB margin below 1 GHz to
FCC Class B when tested in a GTEM with the transceiver
mounted to a circuit card without a chassis enclosure at
frequencies up to 1 GHz. Margins above 1 GHz dependent on
customer board and chassis designs.
Typically show no measurable effect from a 10 V/m field
swept from 27 MHz to 1 GHz applied to the transceiver
without a chassis enclosure.
Accession Number: 9521220 - 36
License Number: 933/510031/03