Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
19 mm Series
PRESSURE SENSOR CHARACTERISTICS – ALL DEVICES
Environmental specifications
Compensated temperature range
Operating temperature range
Storage temperature range
Vibration
0 °C to 82 °C [32 °F to 180 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
10 G at 20 Hz to 2000 Hz
100 G for 11 ms
Shock
Life
1 million cycles min.
Insulation resistance
Maximum ratings
Voltage version “K”
Voltage version “L”
100 mΩ at 50 Vdc
Supply voltage VS = +15 Vdc
Supply current IS = +2.0 mA
PRESSURE RANGE SPECIFICATIONS (19C, 19U)
Catalog Listing
Pressure range
Proof pressure (7)
9 psig
15 psig
30 psig
45 psi
90 psi
150 psi
300 psi
Burst pressure (8)
15 psig
25 psig
50 psig
75 psi
150 psi
250 psi
500 psi
19(C,U) 003P G (1…9) (K/L)
19(C,U) 005P G (1…9) (K/L)
19(C,U) 010P G (1…9) (K/L)
19(C,U) 015P (A,G,V) (1…9) (K/L)
19(C,U) 030P (A,G,V) (1…9) (K/L)
19(C,U) 050P (A,G,V) (1…9) (K/L)
19(C,U) 100P (A,G,V) (1…9) (K/L)
19(C,U) 200P (A,G,V) (1…9) (K/L)
19(C,U) 300P (A,G,V) (1…9) (K/L)
19(C,U) 500P (A,G,V) (1…9) (K/L)
Notes:
0 psig to 3 psig
0 psig to 5 psig
0 psig to 10 psig
0 psi to 15 psi
0 psi to 30 psi
0 psi to 50 psi
0 psi to 100 psi
0 psi to 200 psi
0 psi to 300 psi
0 psi to 500 psi
600 psi
900 psi
1200 psi
1000 psi
1500 psi
2400 psi
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8.The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer case.
(1)
19C SERIES PERFORMANCE CHARACTERISTICS
Characteristic
Minimum
Typical
0
100
50
0.1
0.015
0.010
0.5
0.5
–
Maximum
2
102
52
0.25
0.030
0.030
1.0
1.0
2.0
2.0
0.3
0.3
–
2.0
8.0
50
6.0
Unit
Zero pressure offset
-2
98
48
–
–
–
–
–
–
–
–
–
–
0.5
2.0
8.0
3.0
mV
mV
mV
Full-scale span (2)
Full-scale span (3 psi and 5 psi “K” units only) (2)
Pressure non-linearity (3)
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
ms
Vdc
kΩ
kΩ
kΩ
Pressure hysteresis (3)
Repeatability
Temp. effect on span (4)
Temp. effect on offset (4)
Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only) (4)
Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only) (4)
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
Long-term stability of offset and span (5)
Response time (6)
–
0.1
0.1
0.1
1.3
4.5
25
Common mode voltage (voltage version “K”) (9)
Input impedance (current version “L”)
Input impedance (voltage version “K”)
Output resistance
4.5