CORCOM Product Guide
General Purpose RFI Power Line Filters — Ideal for High Impedance Load
K Series
VK7/EK7
VK6
UL Recognized
CSA Certified
VDE Approved
VK1/EK1
VK3/EK3
K Series
Specifications
Maximum leakage current,each line-to-ground
VK Models
The K series RFI power line filters are general purpose
common-mode and differential-mode filters. They are
effective in the control of line-to-line as well as line-to-
ground RFI interference. The K series RFI filters are
particularly suited in applications where pulsed, continuous
and/or intermittent RFI interference is present. The EK
models meet the very low leakage current requirements of
VDE portable equipment, and (120 Volt) UL544 non-patient
medical equipment.
EK Models
.21 mA
.36 mA
@ 120 VAC 60 Hz:
@ 250 VAC 50 Hz:
Hipot rating (one minute):
line-to-ground
line-to-line
Operating frequency:
.5 mA
1.0 mA
2250 VDC
1450 VDC
50/60 Hz
Rated voltage (max.):
250 VAC
Minimum insertion loss in dB:
Electrical Schematics
Line-to-ground in 50 ohm circuit
Current
Rating
Frequency-MHz
.15
.5
1
5
10
30
LINE
LOAD
VK Models
1A, 3A
15
6
6
30
19
19
22
38
28
28
28
50
42
42
32
50
45
45
39
50
50
50
35
2A, 5A, 10A
20A, 30A, 40A
60A
6
30VK6C Model (Inductor in Ground Line)
EK Models
1A, 3A
2A, 5A, 10A, 20A 8
15
29
19
35
25
45
38
45
40
50
45
LINE
LOAD
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating
VK, EK Models
1A, 3A
2A, 5A, 10A
20A
.15
.5
1
5
10
30
60VK6 Model
–
–
6
–
–
6
48
30
30
55
50
50
50
30
30
35
30
30
LINE
LOAD
VK Models
30A, 40A
60A
EK Models
30A
2
40
49
60
67
65
57
57
53
55
53
13
6
6
30
50
30
30
Resistor location for reference only.
.
74
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
www.corcom.com
www.tycoelectronics.com
reference purposes only.
Specifications subject
to change.
Germany:
49-89-6089-0