产品型号6VJ1-2的Datasheet PDF文件预览

CORCOM Product Guide  
Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for  
General Purpose Applications for UL544 Health Care Equipment  
J Series  
Front View, All Models  
6J4/6J4-2  
Terminal View  
UL Recognized  
CSA Certified  
6HJ4-1/6HJ4-2  
Terminal View  
J Series  
Voltage Selection  
Unfiltered and Filtered Models  
The most widely accepted of all the power entry modules,  
the J series combines an IEC connector, 2-voltage, or 4-  
voltage selection, and a North American fuseholder. It  
features a compact snap-in design and a unique voltage  
selector card.  
J4 Models - This general purpose filter provides  
susceptibility protection from line-to-ground noise on the  
power line and acts as a high frequency clean-up” filter for  
more complex emissions applications.  
HJ4 Models - This medical filter provides susceptibility  
protection without the leakage current associated with line-  
to-ground capacitors. Designed to allow equipment to  
meet UL544 medical specifications for patient care and  
non-patient care equipment, the HJ filter has a maximum  
leakage current of 2µA at 120 VAC 60 Hz. See Appendix  
C for more information on medical applications and UL  
standards.  
Open cover door and rotate fuse-pull lever to left. Select  
operating voltage by orienting voltage selection card,  
desired voltage on top left side. Push card firmly into  
module slot. Rotate fuse-pull lever back into normal  
position and re-insert fuse into holders. Use caution in  
selecting correct fuse value.  
Equipment rating labels and mounting clips for thicker  
panel widths are available as accessories.  
For more information on UL544 specifications, see  
Appendix C.  
Unfiltered Models  
Note: When using the models with an IEC connector,  
remember that the leakage current of the companion line  
cord, GA400, is more significant than that of the filter -  
which may disqualify this line cord from use in patient care  
applications.  
Available Voltage Selection  
Part Number  
6VJ1  
6VJ1-2  
Positions  
4
2
Unfiltered Models  
Available Voltage  
Part Number  
Selection  
Positions  
RFI Filter  
Type  
6VJ4  
6J4-2  
6HJ4-4  
6HJ4-2  
4
2
4
2
General Purpose1  
General Purpose1  
Medical2  
Medical2  
Note 1: General purpose filter for susceptibility applications  
Note 2: Medical line filter for very low leakage UL544 health care requirements  
114  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  
CORCOM Product Guide  
Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for  
General Purpose Applications for UL544 Health Care Equipment (Continued)  
J Series  
Electrical Schematics  
Specifications  
Maximum leakage current, each line-to-ground:  
Filtered 6J4 & 6J4-2  
Note 3  
220V  
240V  
120V  
100V  
6J4  
6EHJ4  
6VJ  
Models Models Models  
500 µA 5 µA  
A
A
B
C
20V  
@250 VAC 50 Hz:  
5 µA  
Power On-Off  
B
C
Off  
Hot  
100V  
Hipot rating (one minute):  
line-to-ground VDC  
line-to-line VAC  
Ground  
Pilot  
light  
On  
D
E
D
E
2250  
1450  
2250  
1450  
1550  
1450  
120V  
Neutral  
J
H
Operating frequency:  
Operating voltages:  
6VJ1, 6J4, 6HJ4-4:  
6J1-2, 6J4-2, 6HJ4-2:  
Rated current:  
50/60 Hz  
F
F
Note 1  
Transformer  
primary  
100, 120, 220, 240 VAC  
115, 230 VAC  
6A  
Filtered 6HJ4-4 & 6HJ4-2  
Fuse (not included):  
Integral fuseholder, line  
side,accepts .25" x 1.25" fuse  
Note 3  
220V  
240V  
120V  
100V  
Terminals:  
Connector block terminals .045" square,  
suitable for soldering, wire wrapping,  
or crimp-on lugs  
A
B
C
A
20V  
Power On-Off  
Off  
B
Hot  
100V  
C
D
Minimum insertion loss in dB:  
Ground  
Pilot  
light  
On  
D
E
Line-to-ground in 50 ohm circuit  
120V  
E
Neutral  
J
H
Current  
Rating  
J4 Models  
6A  
Frequency-MHz  
F
F
Note 1  
Transformer  
.15  
9
.5  
20  
11  
1
5
10  
45  
13  
20  
45  
12  
30  
48  
10  
primary  
25  
15  
41  
19  
Note 1:  
Note 2:  
Note 3:  
Jumper required if only SPST power switch is used.  
Jumpers required if no input filtering is used.  
Use only 120V and 240V positions for 2-volt selection units.  
HJ4 Models  
6A  
9
115  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  
CORCOM Product Guide  
Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for  
General Purpose Applications for UL544 Health Care Equipment (Continued)  
J Series  
Case Styles  
Case Dimensions  
A
B
C
D
Unfiltered Models  
Part No.  
(max)  
2.68  
68.1  
2.75  
69.9  
2.75  
69.9  
(max)  
1.52  
38.6  
1.87  
47.5  
1.87  
47.5  
(max)  
1.17  
29.7  
1.17  
29.7  
1.17  
29.7  
(max)  
1.23  
31.2  
1.58  
40.1  
1.58  
40.1  
.110 [2.79]  
Terminals  
Unfiltered  
6VJ1/6VJ1-2  
Filtered  
Note 5  
6J4/6J4-2  
C
6HJ4-4/6HJ4-2  
D
B
A
Filtered Models  
.110 [2.79]  
Terminals  
Note 5  
C
Recommended Panel Cutout  
Unfiltered and Filtered Models  
Note 4  
D
B
A
1.063* 1.17  
27.0 29.7  
2.60*  
Bezel  
66.0  
2.68  
68.1  
3.00  
Mounting diagram  
(Clearance)  
76.2  
±.003  
Note 4:  
Note 5:  
*
Fuse cover door shown in open condition.  
Standard units mount in panel thickness of .060 - .090"  
Special mounting clips sold separately for panel thickness of  
.105-.125".  
See Accessories List on next page.  
116  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
reference purposes only.  
Specifications subject  
to change.  
Germany:  
49-89-6089-0  
CORCOM Product Guide  
Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for  
General Purpose Applications for UL544 Health Care Equipment (Continued)  
J Series  
Equipment Rating Labels  
Unfiltered and Filtered Models  
Accessories  
Unfiltered and Filtered Models  
Line Cord No. GA400:  
(7 1/2 foot, 3-conductor line cord to mate with J series)  
Self-adhesive labels, as shown below, are available in  
multiples of 40. Specify part number.  
JA302, 2 Voltage Selector Card  
2.330  
(comes standard with 6VJ1-2, 6J4-2, 6HJ4-2)  
240V  
220V  
250mA  
Line V. + 5 - 10%  
48-440 - 50 VA Max.  
100V  
120V  
4-Volt  
.210  
Fuse  
500mA  
JA304, 4 Voltage Selector Card  
(comes standard with 6VJ1, 6J4, 6HJ4-4)  
A
B
C
JA403, Mounting Clips for .105-.125" Panel  
JA500, Voltage Selector Card Extractor Tool  
A
VA  
Max.  
B
Fuse  
C
Fuse  
Part  
Number  
100/120 (115) 220/240 (230)  
JA410  
JA411  
JA412  
JA413  
JA414  
JA415  
JA416  
JA417  
JA418  
JA419  
25  
50  
100  
200  
250  
300  
400  
500  
250 mA  
500 mA  
1A  
2A  
2.5A  
3A  
4 A  
5A  
6A  
125 mA  
250 mA  
500 mA  
1A  
1.25A  
1.5A  
2A  
2.5A  
3A  
600  
Assortment  
JA410-JA418: 40 labels of one part number  
JA419: 5 each JA410 - JA418 (45 labels)  
117  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  
配单直通车
6VJ1-2产品参数
型号:6VJ1-2
Brand Name:CII
是否Rohs认证:符合
生命周期:Active
IHS 制造商:TE CONNECTIVITY LTD
Reach Compliance Code:compliant
Factory Lead Time:18 weeks
风险等级:2.29
Is Samacsys:N
连接器类型:MAINS POWER CONNECTOR
联系完成配合:NOT SPECIFIED
触点性别:MALE
触点材料:NOT SPECIFIED
耦合类型:SNAP
DIN 符合性:NO
IEC 符合性:NO
MIL 符合性:NO
电源连接器额定值:6A, 115/230VAC
安装类型:PANEL
选件:GENERAL PURPOSE
端接类型:SOLDER
触点总数:3
Base Number Matches:1
  •  