ACT2813/ACT2813C
Rev 2, 19-May-15
Recharge
When battery voltage drops by 200mV below the end of charge voltage, the charger is reinitiated with con-
stant current charge.
Figure 3.
Typical Li+ Charge Profile and ACT2813/ACT2813C Charge States
A: PRECONDITION STATE
B: FAST-CHARGE STATE
C: TOP-OFF STATE
D: END-OF-CHARGE STATE
Figure 4.
Charger State Diagram
Innovative PowerTM
- 11 -
www.active-semi.com
Copyright © 2015 Active-Semi, Inc.