ABSOLUTE MAXIMUM RATINGS
Table 5.
Parameter
Input Voltage
Output Short-Circuit Duration
to Ground or V
IN
Storage Temperature
J, RC, and Z Packages
P Package
Operating Temperature Range
REF02A, REF02J, REF02RC
REF02CJ, REF02CZ
REF02CP, REF02CS, REF02E,
REF02H
Lead Temperature Range (Soldering 10 sec)
Rating
40 V
Indefinite
–65°C to +150°C
–65°C to +125°C
–55°C to +125°C
0°C to 70°C
–40°C to +85°C
300°C
Table 6. Package Thermal Resistance
Package Type
TO-99 (J)
8-Lead CERDIP (Z)
8-Lead PDIP (P)
20-Terminal Ceramic LCC (RC)
8-Lead SOIC (S)
θ
JA
170
162
110
120
160
θ
JC
24
26
50
40
44
Unit
°C/W
°C/W
°C/W
°C/W
°C/W
JA
is specified for worst-case mounting conditions, i.e. ,θ
JA
is specified for
device in socket for TO, CERDIP, PDIP, and LCC packages;
θ
JA
is specified for
device soldered to printed circuit board for SOIC packages.
Absolute maximum ratings apply to both DICE packaged parts,
unless otherwise noted.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions outside of those indicated in the operation
sections of this specification is not implied. Exposure to
absolute maximum ratings for extended periods may affect
device reliability.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. F | Page 7 of 16