6
Switching Specifications
For 0°C
≤
T
A
≤
70°C, 4.5 V
≤
V
CC
≤
20 V, all typicals at T
A
= 25°C and V
CC
= 5 V unless otherwise noted.
See note 12.
Parameter
Propagation Delay Time
to Logic High Output Level
Propagation Delay Time
to Logic Low Output Level
Propagation Delay Time
Skew
Output Rise Time
(10-90%)
Output Fall Time
(90-10%)
Common Mode Transient
Immunity at Logic High
Output Level
Symbol
t
PLH
Min.
Typ.
0.3
Max. Units
1.6
µs
µs
µs
ns
Test Conditions
C
O
= 1000 pF,
C
L
= 15 pF,
I
O
= 20 mA
C
O
= 1000 pF,
C
L
= 15 pF,
I
O
= 20 mA
I
O
= 20 mA
I
O
= 20 mA,
C
O
= 1000 pF,
C
L
= 15 pF
I
O
= 20 mA,
C
O
= 1000 pF,
C
L
= 15 pF
V
I
= 2 V,
T
A
= 25°C
V
CM
= 50 V (peak),
V
CC
= 5 V
I
O
(min.) = 12 mA
V
I
= 0.8 V,
T
A
= 25°C
V
CM
= 50 V (peak),
V
CC
= 5 V
I
O
(max.) = 3 mA
Fig.
5, 6,
7
5, 6,
7
Note
6
t
PHL
0.2
1.0
7
t
PLH
- t
PHL
t
r
0.1
16
6, 8
8
t
f
23
ns
6, 8
9
|CM
H
|
1,000 10,000
V/µs
9, 10
10
Common Mode Transient
Immunity at Logic Low
Output Level
|CM
L
|
1,000 10,000
V/µs
9, 10
11
Package Characteristics
For 0°C
≤
T
A
≤
70°C, unless otherwise specified. All typicals at T
A
= 25°C.
Parameter
Symbol Min. Typ. Max. Units
Test Conditions
Input-Output Momentary
V
ISO
2500
V rms RH
≤
50%, t = 1 min,
Withstand Voltage*
T
A
= 25°C
Resistance, Input-Output
R
I-O
10
12
ohms V
I-O
= 500 V dc
Capacitance, Input-Output
C
I-O
1
pF
f = 1 MHz,
V
I-O
= 0 V dc
Fig. Notes
5, 13
5
5
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable),