Recommended Operating Conditions
Parameter
Power Supply Voltage
Forward Input Current (ON)
HCPL-223X
Forward Input Voltage (OFF)
Operating Temperature
Junction Temperature
Fan Out
V
F(OFF)
T
A
T
J
N
Symbol
V
CC
I
F(ON)
Min.
4.5
1.6*
1.8†
-
-40
-40
Max.
20
5
0.8
85
125
4
Units
V
mA
V
°C
°C
TTL Loads
*The initial switching threshold is 1.6 mA or less. It is recommended that 2.2 mA be used to permit at least a 20% LED degradation
guardband.
†The initial switching threshold is 1.8 mA or less. It is recommended that 2.5 mA be used to permit at least a 20% LED degradation
guardband.
Electrical Specifications
-40°C
≤
T
A
≤
85°C, 4.5 V
≤
V
CC
≤
20 V, 1.6 mA
≤
I
F(ON)
*
≤
5 mA, 0 V
≤
V
F(OFF)
≤
0.8 V, unless otherwise
specified. All Typicals at T
A
= 25°C. See Note 7.
Parameter
Logic Low Output Voltage
Logic High Output Voltage
Output Leakage Current
(V
OUT
> V
CC
)
Logic Low Supply
Current
HCPL-223X
Logic High Supply
Current
HCPL-223X
Logic Low Short Circuit
Output Current
Logic High Short Circuit
Output Current
Input Forward Voltage
HCNW22XX
Input Reverse Breakdown
Voltage
HCNW22XX
Input Diode Temperature
Coefficient
HCNW22XX
Input Capacitance
HCNW22XX
BV
R
∆V
F
∆T
A
C
IN
I
CCH
Sym.
V
OL
V
OH
I
OHH
I
CCL
Min. Typ. Max. Units
Test Conditions
Fig. Note
0.5
V
I
OL
= 6.4 mA (4 TTL Loads) 1, 3
1
2.4
**
V
I
OH
= -2.6 mA
2, 3,
1
8
2.7
I
OH
= -0.4 mA
100
µA
V
O
= 5.5 V
I
F
= 5 mA
1
500
V
O
= 20 V
3.7
6.0
mA V
CC
= 5.5 V
V
F
= 0 V
I
O
= Open
4.3
7.0
V
CC
= 20 V
7.4 12.0
V
CC
= 5.5 V
8.6 14.0
V
CC
= 20 V
2.4
4.0
mA V
CC
= 5.5 V
I
F
= 5 mA
I
O
= Open
2.7
5.0
V
CC
= 20 V
4.8
8.0
V
CC
= 5.5 V
5.4 10.0
V
CC
= 20 V
15
mA V
O
= V
CC
= 5.5 V V
F
= 0 V
1, 3
20
V
O
= V
CC
= 20 V
-10
mA V
CC
= 5.5 V
I
F
= 5 mA
1, 3
V
O
= GND
-20
V
CC
= 20 V
1.5
1.7
V
T
A
= 25°C
I
F
= 5 mA
4
1
1.85
1.5 1.82
T
A
= 25°C
1.95
5
V
I
R
= 10
µA
1
3
I
R
= 100
µA
-1.7
mV/°C
I
F
= 5 mA
-1.4
60
pF
f = 1 MHz, V
F
= 0 V
1, 4
70
I
OSL
I
OSH
V
F
*For HCPL-223X, 1.8 mA
≤
I
F(ON)
≤
5 mA.
**Typical V
OH
= V
CC
- 2.1 V.
1-139