Absolute Maximum Ratings at T
A
= 25
°
C
Parameter
Peak Forward Current
Average Forward Current
[1]
DC Current
[2]
Reverse Voltage (I
R
= 100
µA)
Transient Forward Current
[4]
(10
µsec
Pulse)
LED Junction Temperature
Operating Temperature Range
Storage Temperature Range
Lead Soldering Temperature
[1.6 mm (0.063 in.) from body]
HER/Orange
90
25
30
5
500
110
-55 to +100
Yellow
60
20
20
5
500
110
-55 to +100
Green
90
25
30
5
500
110
-20 to +100
-55 to +100
260°C for 5 seconds
Units
mA
mA
mA
V
mA
°C
°C
Notes:
1. See Figure 5 (HER/Orange), 10 (Yellow), or 15 (Green/Emerald Green) to establish pulsed operating conditions.
2. For Red, Orange, and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. For Red, Orange, and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at
1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED
die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the
Absolute Maximum Ratings.
Electrical Characteristics at T
A
= 25
°
C
Symbol
I
V
Description
Luminous Intensity
Device
HLMP-
High Efficiency Red
1300
1301
1302
1385
Orange
K400
K401
K402
Yellow
1400
1401
1402
1485
Green
1503
1523
1585
Emerald Green
K600
Min.
1.3
2.1
3.4
8.6
1.3
2.1
3.4
1.4
2.2
3.6
5.7
1.0
2.6
4.2
1.0
Typ.
5.0
5.5
7.0
11.0
5.0
5.5
7.0
5.0
6.0
7.0
10.0
5.0
7.0
8.5
4.5
Max.
Units
mcd
Test
Conditions
I
F
= 10 mA