AGB3300
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PAR AMETER
D evi ce Voltage
RF Input Power
Storage Temperature
C hannel Temperature
MIN
0
-
-40
-
MAX
+8
+15
+150
+150
U N IT
VD C
dB m
°C
°C
Stresses in excess of the absolute ratings may cause permanent
damage. Functional operation is not implied under these conditions.
Exposure to absolute ratings for extended periods of time may
adversely affect reliability.
Table 3: Operating Ranges
PAR AMETER
Operati ng Frequency: f
D evi ce Voltage: V
DD
C ase Temperature: T
c
MIN
250
-
-40
TYP
-
+5
-
MAX
3000
+6
+85
U N IT
MHz
VD C
o
C
The device may be operated safely over these conditions; however,
parametric performance is guaranteed only over the conditions defined
in the electrical specifications.
Data Sheet - Rev 2.1
06/2003
3