AAT2856  
High Current Charge Pump with  
Dual LDO for BacklightApplications  
Since only one of the scales can be active at any  
given time, the 20mA and 30mA scales cannot be  
mixed between main and sub. When setting Address  
12 to the 30mA scale, only current levels from that  
scale can be mixed between main and sub.  
Data  
1
2
3
4
5
6
7
8
BL6  
BL5  
BL4  
BL3  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Data  
Maximum Current  
1
2
20mA  
30mA  
Table 6: Address 12 Maximum Current  
Settings.  
9
10  
11  
12  
13  
14  
15  
16  
Backlight Independent Channel Control  
(Address 15)  
The AAT2856 has a unique independent channel  
control mode whereby individual backlight LED  
channels can be enabled and disabled to form a  
custom arrangement of active channels.  
Table 8: Sub-Address 2: BL3-BL6  
On/Off Control.  
To enable independent channel control mode, write  
Data 8 to Address 15. To exit individual mode con-  
trol, the AAT2856 state machine can be reset by  
strobing ENS low and holding ENS low longer than  
Data  
BL2  
BL1  
2
1
2
3
4
5
6
7
8
9
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
the A SCwire's tOFF latch time.  
Data  
Individual Backlight Control  
8
On  
Table 7: Address 15, Independent  
Backlight Control.  
With independent channel control mode enabled,  
Addresses 2 and 3 are re-mapped according to  
Tables 8 and 9. As indicated by the possible set-  
tings listed in the tables, any combination of back-  
lighting channels can be enabled and disabled.  
10  
11  
12  
13  
14  
15  
16  
Table 9: Sub-Address 3: BL1 and BL2  
On/Off Control.  
Because Addresses 2 and 3 are re-mapped when  
independent channel control mode is enabled, the  
functions originally assigned to Addresses 2 and 3  
are no longer available.  
2856.2007.06.1.0  
13