欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-3760 参数 Datasheet PDF下载

HCPL-3760图片预览
型号: HCPL-3760
PDF下载: 下载PDF文件 查看货源
内容描述: 隔离型电压/电流检测器 [Isolated Voltage/Current Detectors]
分类和应用: 光电输出元件
文件页数/大小: 14 页 / 374 K
品牌: AVAGO [ AVAGO TECHNOLOGIES LIMITED ]
 浏览型号HCPL-3760的Datasheet PDF文件第5页浏览型号HCPL-3760的Datasheet PDF文件第6页浏览型号HCPL-3760的Datasheet PDF文件第7页浏览型号HCPL-3760的Datasheet PDF文件第8页浏览型号HCPL-3760的Datasheet PDF文件第10页浏览型号HCPL-3760的Datasheet PDF文件第11页浏览型号HCPL-3760的Datasheet PDF文件第12页浏览型号HCPL-3760的Datasheet PDF文件第13页  
Switching Specifications  
TA = 25°C, VCC = 5.0 V, Unless Otherwise Specified.  
Parameter  
Sym.  
Device  
Min. Typ. Max. Units  
Test Conditions  
Fig.  
Note  
Propagation Delay  
Time to Logic Low  
at Output  
HCPL-0370/3700  
4.0  
tPHL  
15.0  
40.0  
µs  
µs  
RL = 4.7 kW, CL = 30 pF  
10  
HCPL-3760  
4.5  
7, 10  
Propagation Delay  
Time to Logic High  
at Output  
HCPL-0370/3700  
10.0  
tPLH  
RL = 4.7 kW, CL = 30 pF  
RL = 4.7 kW, CL = 30 pF  
11  
HCPL-3760  
8.0  
20  
HCPL-0370/3700  
Output Rise Time  
(10-90%)  
tr  
tf  
µs  
µs  
HCPL-3760  
14  
8
HCPL-0370/3700  
0.3  
Output Fall Time  
(90-10%)  
RL = 4.7 kW, CL = 30 pF  
IIN = 0 mA, RL = 4.7 kW,  
HCPL-3760  
0.4  
Common Mode  
Transient Immunity |CMH|  
at Logic High Output  
4000  
V/µs VO min = 2.0 V, VCM = 1400 V  
9, 11 12, 13  
Common Mode  
Transient Immunity |CML|  
at Logic Low Output  
HCPL-0370/3700  
HCPL-3760  
IIN = 3.11 mA RL = 4.7 kW,  
VO max = 0.8 V,  
IIN = 1.56 mA VCM = 140 V  
600  
V/µs  
Package Characteristics  
Over Recommended Temperature T = 0°C to 70°C, Unless Otherwise Specified.  
A
Parameter  
Sym.  
Min.  
Typ.[9]  
Max.  
Units  
Conditions  
Fig.  
Note  
Input-Output Momentary  
Withstand Voltage*  
Option 020  
V
3750  
V rms  
RH 50%, t = 1 min;  
16,  
17  
18  
ISO  
T = 25°C  
A
5000  
Input-Output Resistance  
Input-Output Capacitance  
RI-O  
CI-O  
1012  
0.6  
W
V
I-O = 500 Vdc  
16  
pF  
f = 1 MHz; VI-O = 0 Vdc  
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous volt-  
age rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-5 Insulation Characteristics Table (if applicable), your equipment  
level safety specification, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”  
9