Switching Specifications
TA = 25°C, VCC = 5.0 V, Unless Otherwise Specified.
Parameter
Sym.
Device
Min. Typ. Max. Units
Test Conditions
Fig.
Note
Propagation Delay
Time to Logic Low
at Output
HCPL-0370/3700
4.0
tPHL
15.0
40.0
µs
µs
RL = 4.7 kW, CL = 30 pF
10
HCPL-3760
4.5
7, 10
Propagation Delay
Time to Logic High
at Output
HCPL-0370/3700
10.0
tPLH
RL = 4.7 kW, CL = 30 pF
RL = 4.7 kW, CL = 30 pF
11
HCPL-3760
8.0
20
HCPL-0370/3700
Output Rise Time
(10-90%)
tr
tf
µs
µs
HCPL-3760
14
8
HCPL-0370/3700
0.3
Output Fall Time
(90-10%)
RL = 4.7 kW, CL = 30 pF
IIN = 0 mA, RL = 4.7 kW,
HCPL-3760
0.4
Common Mode
Transient Immunity |CMH|
at Logic High Output
4000
V/µs VO min = 2.0 V, VCM = 1400 V
9, 11 12, 13
Common Mode
Transient Immunity |CML|
at Logic Low Output
HCPL-0370/3700
HCPL-3760
IIN = 3.11 mA RL = 4.7 kW,
VO max = 0.8 V,
IIN = 1.56 mA VCM = 140 V
600
V/µs
Package Characteristics
Over Recommended Temperature T = 0°C to 70°C, Unless Otherwise Specified.
A
Parameter
Sym.
Min.
Typ.[9]
Max.
Units
Conditions
Fig.
Note
Input-Output Momentary
Withstand Voltage*
Option 020
V
3750
V rms
RH 50%, t = 1 min;
16,
17
18
ISO
T = 25°C
A
5000
Input-Output Resistance
Input-Output Capacitance
RI-O
CI-O
1012
0.6
W
V
I-O = 500 Vdc
16
pF
f = 1 MHz; VI-O = 0 Vdc
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous volt-
age rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-5 Insulation Characteristics Table (if applicable), your equipment
level safety specification, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
9