TYPICAL PERFORMANCE CURVES (Cont.)
At TA = +25°C, VS = ±15V, G = 0.1, RL = 10kΩ connected to ground and Ref pin connected to ground, unless otherwise noted.
QUIESCENT CURRENT AND
SHORT-CIRCUIT CURRENT vs TEMPERATURE
SLEW RATE vs TEMPERATURE
670
650
630
610
590
570
550
530
510
490
470
20
18
16
14
12
10
8
0.6
0.55
0.5
G = 1
G = 1
ISC
0.45
0.4
IQ
0.35
0.3
6
4
0.25
0.2
2
0
–60 –40 –20
0
20
40
60 80 100
140
120
–60 –40 –20
0
20
40
60 80 100
140
120
Temperature (°C)
Temperature (°C)
GAIN AND PHASE vs FREQUENCY
Op Amp A1 and A2
SETTLING TIME vs LOAD CAPACITANCE
120
100
80
60
40
20
0
110
100
90
80
70
60
50
40
30
20
10
0
TS vs CLOAD
VS = ±15V
0.01%, G = 1
G
RL = 10kΩ || 200pF
Φ
–90
RL = 10kΩ || 1nF
0.1%, G = 0.1
–135
–180
0.1%, G = 1
–10
1
3
10
30
100
1
10
100
1k
Frequency (Hz)
10k
100k
1M
Load Capacitance (nF)
MAXIMUM OUTPUT VOLTAGE SWING
vs OUTPUT CURRENT
OFFSET VOLTAGE
PRODUCTION DISTRIBUTION
Typical production
S = ±2.25V
15
10
5
25
20
15
10
5
+85°C
V
distribution of
–25°C
+25°C
packaged units.
+125°C
+85°C
0
–55°C
+125°C
–5
–10
–15
+25°C
–25°C
+85°C
0
0
2
4
6
8
10
12
14
16
Output Current (mA)
Offset Voltage, RTI (mV)
®
6
INA146