 浏览型号REG103UA-3.3G4的Datasheet PDF文件第7页浏览型号REG103UA-3.3G4的Datasheet PDF文件第8页浏览型号REG103UA-3.3G4的Datasheet PDF文件第9页浏览型号REG103UA-3.3G4的Datasheet PDF文件第10页浏览型号REG103UA-3.3G4的Datasheet PDF文件第12页浏览型号REG103UA-3.3G4的Datasheet PDF文件第13页浏览型号REG103UA-3.3G4的Datasheet PDF文件第14页浏览型号REG103UA-3.3G4的Datasheet PDF文件第15页  
For large step changes in load current, the REG103 requires  
a larger voltage drop across it to avoid degraded transient  
response. The boundary of this “transient drop-out” region is  
shown as the top line in Figure 10. Values of VIN to VOUT  
voltage drop above this line insure normal transient response.  
limited to 125°C, maximum. To estimate the margin of  
safety in a complete design (including heat sink), increase  
the ambient temperature until the thermal protection is  
triggered. Use worst-case loads and signal conditions. For  
good reliability, thermal protection should trigger more than  
35°C above the maximum expected ambient condition of  
your application. This produces a worst-case junction tem-  
perature of 125°C at the highest expected ambient tempera-  
ture and worst-case load.  
REG1033.3 at 25°C  
250  
DC  
Transient  
200  
The internal protection circuitry of the REG103 has been  
designed to protect against overload conditions. It was not  
intended to replace proper heat sinking. Continuously run-  
ning the REG103 into thermal shutdown will degrade reli-  
ability.  
150  
100  
50  
POWER DISSIPATION  
The REG103 is available in three different package configu-  
rations. The ability to remove heat from the die is different  
for each package type and, therefore, presents different  
considerations in the printed circuit board (PCB) layout. The  
PCB area around the device that is free of other components  
moves the heat from the device to the ambient air. While it  
is difficult to impossible to quantify all of the variables in a  
thermal design of this type, performance data for several  
configurations are shown in Figure 11. In all cases, the PCB  
copper area is bare copper, free of solder-resist mask, and  
not solder plated. All examples are for 1-ounce copper.  
Using heavier copper will increase the effectiveness in  
moving the heat from the device. In those examples where  
there is copper on both sides of the PCB, no connection has  
been provided between the two sides. The addition of plated  
through holes will improve the heat sink effectiveness.  
0
0
100  
200  
300  
400  
500  
IOUT (mA)  
FIGURE 10. Transient and DC Dropout.  
In the transient dropout region between “DC” and “Tran-  
sient”, transient response recovery time increases. The time  
required to recover from a load transient is a function of both  
the magnitude and rate of the step change in load current and  
the available “headroom” VIN to VOUT voltage drop. Under  
worst-case conditions (full-scale load change with VIN to  
VOUT voltage drop close to DC dropout levels), the REG103  
can take several hundred microseconds to re-enter the speci-  
fied window of regulation.  
6
TRANSIENT RESPONSE  
CONDITIONS  
The REG103 response to transient line and load conditions  
improves at lower output voltages. The addition of a capaci-  
tor (nominal value 10nF) from the output pin to ground may  
improve the transient response. In the adjustable version, the  
addition of a capacitor, CFB (nominal value 10nF), from the  
output to the adjust pin will also improve the transient  
response.  
#1  
#2  
#3  
#4  
#5  
5
4
3
2
1
0
THERMAL PROTECTION  
Power dissipated within the REG103 will cause the junction  
temperature to rise. The REG103 has thermal shutdown  
circuitry that protects the regulator from damage. The ther-  
mal protection circuitry disables the output when the junc-  
tion temperature reaches approximately 150°C, allowing the  
device to cool. When the junction temperature cools to  
approximately 130°C, the output circuitry is again enabled.  
Depending on various conditions, the thermal protection  
circuit may cycle on and off. This limits the dissipation of  
the regulator, but may have an undesirable effect on the load.  
0
25  
50  
75  
100  
125  
150  
Ambient Temperature (°C)  
CONDITION  
PACKAGE  
PCB AREA  
θJA  
1
2
3
DDPAK  
SOT-223  
DDPAK  
4in2 Top Side Only  
4in2 Top Side Only  
None  
0.5in2 Top Side Only  
None  
27°C/W  
53°C/W  
65°C/W  
4
5
SOT-223  
SO-8  
110°C/W  
150°C/W  
Any tendency to activate the thermal protection circuit  
indicates excessive power dissipation or an inadequate heat  
sink. For reliable operation, junction temperature should be  
FIGURE 11. Maximum Power Dissipation versus Ambient  
Temperature for the Various Packages and  
PCB Heat Sink Configurations.  
REG103  
SBVS010D  
11