欢迎访问ic37.com |
会员登录 免费注册
发布采购

BL6506 参数 Datasheet PDF下载

BL6506图片预览
型号: BL6506
PDF下载: 下载PDF文件 查看货源
内容描述: 单相电能计量芯片集成振荡器 [Single Phase Energy Meter IC with Integrated Oscillator]
分类和应用: 振荡器
文件页数/大小: 14 页 / 467 K
品牌: BELLING [ SHANGHAI BELLING CO., LTD. ]
 浏览型号BL6506的Datasheet PDF文件第2页浏览型号BL6506的Datasheet PDF文件第3页浏览型号BL6506的Datasheet PDF文件第4页浏览型号BL6506的Datasheet PDF文件第5页浏览型号BL6506的Datasheet PDF文件第6页浏览型号BL6506的Datasheet PDF文件第7页浏览型号BL6506的Datasheet PDF文件第8页浏览型号BL6506的Datasheet PDF文件第9页  
BL6506
FEATURES
High accuracy, less than 0.1% error over a
dynamic range of 500: 1
On-chip oscillator as clock source
Exactly measure the real power in the positive
orientation and negative orientation, calculate the
energy in the same orientation
Two current monitors continuously monitor the
phase and neutral currents in two-wire distribution
systems. Uses the larger of two currents to bill, even
during a Fault condition
A PGA in the current channel allows using small
value shunt and burden resistance
The low frequency outputs F1 and F2 can
directly drive electromechanical counters and two
phase stepper motors and the high frequency output
CF, supplies instantaneous real power, is intended for
calibration and communications
Two logic outputs REVP and FAULT can be used
to indicate a potential orientation or Fault condition
On-Chip power supply detector
On-Chip anti-creep protection
On-Chip voltage reference of 2.5V±8%
Single 5V supply
Low static power (typical value of 25mW).
The technology of SLiM (Smart–Low–current–
Management) is used.
Credible work, working time is more than twenty
years
Single Phase Energy Meter IC
with Integrated Oscillator
DESCRIPTION
The BL6506 is a low cost, high accuracy, high
stability, simple peripheral circuit electrical energy
meter IC. The meter based on the BL6506 is intended
for using in single-phase, two-wire distribution
systems. It can exactly measure the real power in the
positive orientation and negative orientation and
calculate the energy in the same orientation.
The BL6506 incorporates a novel fault detection
scheme that both warns of fault conditions and allows
the BL6506 to continue accurate billing during a fault
event. The BL6506 does this by continuously
monitoring both the phase and neutral (return)
currents. PIN15 (FAULT) indicates Fault condition,
when these currents differ by more than 12.5%.
Billing is continued using the larger of the two
currents when the difference is greater than 14%.
The BL6506 supplies average real power
information on the low frequency outputs F1 (Pin20)
and F2 (Pin19). These logic outputs may be used to
directly drive an electromechanical counter and
two-phase stepper motors. The CF (Pin18) logic
output gives instantaneous real power information.
This output is intended to be used for calibration
purposes or interface to an MCU.
BL6506 thinks over the stability of reading
error in the process of calibration. Bulk test data
indicate that in the condition of small signal 5%Ib
(Ib=5A), the error of CF is less than 0.1%. An internal
no-load threshold ensures that the BL6506 does not
Interrelated patents are pending
exhibit any creep when there is no load.
BLOCK DIAGRAM
SSOP 20
http://www.belling.com.cn
-1-
Total
14 Pages
3/15/2007