欢迎访问ic37.com |
会员登录 免费注册
发布采购

1740-35 参数 Datasheet PDF下载

1740-35图片预览
型号: 1740-35
PDF下载: 下载PDF文件 查看货源
内容描述: 同轴浪涌保护器 [Coaxial Surge Protector]
分类和应用:
文件页数/大小: 2 页 / 172 K
品牌: BOURNS [ BOURNS ELECTRONIC SOLUTIONS ]
 浏览型号1740-35的Datasheet PDF文件第2页  
Features
Protects subscribers and equipment from
destructive power crosses and lightning
surges
Compact size fits subscriber network in-
terface devices
Reduces frequency of service calls
Increases reliability of network operation
Reduces cost of network maintenance
UL
Listed per 497 C
Patent # 5,508,873 (U.S.);
#2,169,604 (Canada)
®
1740 Series – Coaxial Surge Protector
75 Ohm Powered & Unpowered Coax DC to >1 GHz
The Bourns 1740 Series of Primary Broadband Coaxial Surge Protectors is designed for Network and other high frequency
applications. The 1740 Series provides protection against surges on 75 ohm coax subscriber drops and has a fail-short
mechanism in the event of dangerous power-crosses. The protector will pass bi-directional signals over the bandwidth from
DC to in excess of 1 Ghz. Its cast-metal housing and environmentally sealed design will withstand the toughest Outside Plant
Applications.
Characteristics
Min. Band Width/Frequency Characteristics
DC to 1.0 GHz
DC to 1.25 GHz
Connectors, Input & Output ............................................ F-Type (female) .................................. F-Type (female)
Characteristic Impedance ............................................... 75
.........................................................
75
Transmission/Insertion Loss (Max.) ................................ 0.15 dB ............................................... 0.45 dB
Return Loss (Max.) ..................................................... 20 dB .................................................. 13 dB
VSWR (Max.) ............................................................. 1:1.22 ................................................. 1:1.57
Min Fail-Short, Power Cross & Sustained
60 Hz Current Capability
1000 Vrms Open-Circuit Voltage, 25
°C
..................... 30 Arms Line to Ground ..................... 15 minutes
60 Arms Line to Ground
5 seconds
120 Arms Line to Ground
5 seconds
350 Arms Line to Ground
200 mseconds
Capacitance ............................................................... 1 MHz, 1 Vrms, 0 Vdc ........................ <10 pF
Insulation Resistance ................................................. 100 V .................................................. >10
8
Operating Temperature .............................................. -40
°C
to 65
°C
(-40
°F
to 149
°F)
...... -40
°C
to 65
°C
(-40
°F
to 149
°F)
Storage Temperature .................................................. -55
°C
to 85
°C
(-67
°F
to 185
°F)
...... -55
°C
to 85
°C
(-67
°F
to 185
°F)
SURGE PROTECTION CHARACTERISTICS
Model
No.
DC Breakdown
@ 100 V/Sec (Volts)
Typical Impulse
Breakdown
@ 100 V/µs
(Volts)
Service Life, Lightning
Service Life, AC, 60 Hz
100 A
5 kA
20 kA
5A
10 A
10/1000
µs
8/20
µs
8/20
µs
1000 Vac 1 sec 1000 Vac 1 sec
(Operations)
(Operations) (Operations)
(Operations)
(Operations)
IMPULSE RESET
52.5Vdc
@ 260 mA 135 Vdc
@ 200 mA
(Millisec)
1740-15
1740-23
1740-35
150
±20
%
230
±20
%
350
±20
%
350
450
650
>1000
>1000
>1000
>10
>10
>10
>1
>1
>1
20
20
20
10
10
10
<150
<150
<150
Product Dimensions
DIMENSIONS:
81.28
(3.20)
55.88
(2.20)
MILLIMETERS
(INCHES)
12.70
(.50)
F TYPE CONNECTOR
3/8-32 THREAD
12.70
(.50)
38.10
(1.50)
19.05
(.75)
9.40
(.37)
REV. L
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.