欢迎访问ic37.com |
会员登录 免费注册
发布采购

1965-50-A01 参数 Datasheet PDF下载

1965-50-A01图片预览
型号: 1965-50-A01
PDF下载: 下载PDF文件 查看货源
内容描述: 50欧姆同轴浪涌保护器 [50 Ohm Coaxial Surge Protector]
分类和应用:
文件页数/大小: 2 页 / 105 K
品牌: BOURNS [ BOURNS ELECTRONIC SOLUTIONS ]
 浏览型号1965-50-A01的Datasheet PDF文件第2页  
Features
Protects subscribers and equipment from destructive power crosses and lightning surges
Reduces frequency of service calls
Increases reliability of network operation
Reduces cost of network maintenance
UL
®
Listed per UL 497*
1965 Series – 50 Ohm Coaxial Surge Protector
The Bourns 1965 Series Coaxial Surge Protector is intended for use with low power VHF and UHF transmitters, 2-way base station
transceivers, and receive-only systems. All models provide GDT technology. The 1965 arrester is symmetric and bidirectional. Either
end may be used for the input or output. Various power and voltage choices are available - see specifications below for proper
selection. Available with a choice of connectors.
Note: The arrester ground plate is common with the connector body; hence the coax cable shields will be grounded at their
connection to the arrester.
Characteristics
Characteristic Impedance ..................................................................................................................... 50
Ω
Frequency Characteristics (DC - 1 GHz)
VSWR (Max.) .................................................................................................................................... <1.2:1
Transmission/Insertion Loss (Max.).................................................................................................. <0.2 dB
Impulse Discharge
20 kA, 8/20 µs .................................................................................................................................. 1 time
10 kA, 8/20 µs .................................................................................................................................. 10 times
500 A, 10/1000 µs ............................................................................................................................ 500 times
Arc Voltage (during discharge) .............................................................................................................. 10 V
Operating Temperature.......................................................................................................................... -40 ° to +85 °C
Maximum Operating Altitude ................................................................................................................ 7,000 m
Impulse Sparkover (100 V/µs)
1965-20*
1965-35
1965-50
1965-60
100 V/µs ..............................................400 V ...................... 550 V ....................... 700 V .................. 600 V
1 kV/µs ................................................500 V ...................... 650 V ....................... 800 V .................. 850 V
10 kV/µs ..............................................650 V ...................... 800 V ....................... 900 V .................. 1100 V
*Model 1965-20-Axx is UL Listed per UL 497 for indoor/outdoor use in a listed, compatible NID.
VSWR and Insertion Loss
0
.025
.050
1.00
1.02
1.04
1.06
VSWR
Insertion
Loss
(-dB)
.075
.100
.125
.150
.175
.200
0
100
200
300
400
500
600
700
800
900
1000
INSERTION LOSS
1.08
1.10
1.12
1.14
1.16
VSWR
Frequency (MHz)
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications