BRIGHT VIEW
ELECTRONICS CO.,LTD
ULTRA BRIGHTNESS LED LAMP
PACKAGE CONFIGURATION
5.9
5.9
BVU-5A6WI5
DESCRIPTION
Dice Material : GaN Blue
Light Color : White Color
Lens Color : Water Transparent
Stand-Off P/N : BVU-5A6WI5 R
5.0
4.9
RADIATION PATTERN
1.0
7.6
12.0 0.5
1.0Max.
1.3
25.4Min.
CATHODE
0.5
2.54
1.0Min.
2.54
CATHODE
1.0
25.4Min.
Tolerance ± 0.25
㎜
ABSOLUTE MAXIMUM RATINGS AT Ta = 25
℃
PARAMETER
Power Dissipation (P
D
)
Continuous Forward Current (I
F
)
Peak Forward Current ( 1/10 Duty Cycle , 10ms Pulse Width ) (I
FP
)
Reverse Voltage (V
R
)
MAX.
120
30
100
5
UNIT
mW
mA
mA
V
mA/
o
C
0.4
Derating Linear From 25
℃
Operating Temperature Range (Topr)
-30 ℃
to
+
85
℃
Storage Temperature Range (Tstg)
-40
℃
to
+
100
℃
Lead Solder Temperature 1.6 mm Below Package 260
℃
for 5 seconds (Tsld)
ELECTRICAL / OPTICAL CHARACTERISTICS AT Ta = 25
℃
SYMBOL
V
F
I
R
2θ1/2
I
V
Bin
Min.
Max.
PARAMETER
Forward Voltage
Reverse Current
Viewing Angle
Luminous Intensity
M
2180
2800
x
y
x
y
x
y
x
y
N
2800
3600
0.26
0.2
0.275
0.22
0.29
0.24
0.305
0.265
O
3600
4650
0.26
0.24
0.275
0.26
0.29
0.28
0.305
0.305
TEST COND.
I
F
= 20 mA
V
R
= 5V
I
F
= 20 mA
I
F
= 20 mA
P
4650
6000
Q
6000
7800
MIN.
TYP.
3.2
60
2800
MAX.
4.0
10
UNIT
V
μA
Deg
mcd
2180
BIN GRADE LIMITS (IF=20 mA) LUMINOUS INTENSITY / mcd
Tolerance ± 15%mcd
Please contact our sales department for more
information.
x
y
x
y
x
y
x
y
0.32
0.29
0.31
0.35
0.33
0.35
0.32
0.33
0.35
0.35
0.37
0.39
0.335
0.35
0.35
0.37
0.365
0.39
0.38
0.41
0.335
0.31
0.35
0.33
0.365
0.35
0.38
0.37
BIN GRADE LIMITS (IF=20 mA) CHROMATICITY COORDINATES
WA1
WA2
WB1
WB2
0.275 0.275
0.26
0.29
0.28
0.22
0.29
0.24
WC1
WC2
WD1
WD2
0.335 0.335
0.305 0.305
0.305 0.265
0.32
0.33
0.32
0.29
0.365 0.365
*Bright View reserves the rights to alter specifications and remove availability of products at any time without notice.
*Dominant Wavelength,
λd
is according to CIE Chromaticity Diagram base on color of lamps.
*
θ
1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
*These products are sensitive to static electricity. Caution must be taken strictly to avoid static electricity.
2009/10/14 – A