4.0 Serial Interface  
CN8478/CN8474A/CN8472A/CN8471A  
4.1 Serial Port Interface  
Multichannel Synchronous Communications Controller (MUSYCC™)  
4.1 Serial Port Interface  
A receive serial port interface (Rx-SERI) connects to four input signals: RCLK,  
RDAT, RSYNC, and ROOF. A transmit serial port interface (Tx-SERI) connects  
to two input signals and one output signal, TCLK, TSYNC, and TDAT,  
respectively (refer to Table 1-4, CN8478 Hardware Signal Definitions). The SERI  
is responsible for receiving and transmitting data bits to FIFO buffers in the BLP.  
The receive and transmit data and synchronization signals are synchronous to  
the receive and transmit line clocks, respectively. MUSYCC can be configured to  
sample in and latch out data signals and sample in status and synchronization  
signals on either the rising or falling edges of the respective line clock, RCLK and  
TCLK. This configuration is accomplished by setting the ROOF_EDGE,  
RSYNC_EDGE, RDAT_EDGE, TSYNC_EDGE, and TDAT_EDGE bit fields  
(detailed in Table 5-12, Port Configuration Descriptor).  
The default, after device reset, is to sample in and latch out data,  
synchronization, and status on the falling edges of the respective line clock.  
4.2 Bit Level Processor  
The bit-level processors (Rx-BLP and Tx-BLP) service the bits in the receive and  
transmit path. As internal FIFO buffers are filled and flushed, the BLP requests  
memory transfers from the DMAC. The BLP coordinates all bit-level transactions  
between SERI and DMAC. The BLP also interacts with the INTC to notify the  
host of events and errors during bit-level processing.  
4.3 DMA Controller  
The DMA controllers (Rx-DMAC and Tx-DMAC) manage all memory  
operations between a corresponding BLP and the host interface. DMAC takes  
requests from BLP to either fill or flush internal FIFO buffers, sets up an access  
to data buffers in shared memory, and requests access to the PCI bus through the  
host interface.  
4.4 Interrupt Controller  
The interrupt controller takes receive and transmit events from Rx-BLP and  
Tx-BLP, respectively. The INTC coordinates the transfer of internally queued  
descriptors to an interrupt queue in shared memory and also coordinates the  
notification to the host of pending interrupts.  
4-2  
Conexant  
100660E