CY74FCT2374T
8-BIT REGISTER
WITH 3-STATE OUTPUTS
SCCS040A – SEPTEMBER 1994 – REVISED OCTOBER 2001
timing requirements over recommended operating free-air temperature range (unless otherwise
noted) (see Figure 1)
CY74FCT2374T
MIN
tw
tsu
th
Pulse duration, CP
Setup time, data before CP↑
Hold time, data after CP↑
7
2
1.5
MAX
CY74FCT2374AT
MIN
5
2
1.5
MAX
CY74FCT2374CT
MIN
4
1.5
1
MAX
UNIT
ns
ns
ns
switching characteristics over operating free-air temperature range (see Figure 1)
PARAMETER
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
FROM
(INPUT)
CP
TO
(OUTPUT)
O
O
O
CY74FCT2374T
MIN
2
2
1.5
1.5
1.5
1.5
MAX
10
10
12.5
12.5
8
8
CY74FCT2374AT
MIN
2
2
1.5
1.5
1.5
1.5
MAX
6.5
6.5
6.5
6.5
5.5
5.5
CY74FCT2374CT
MIN
2
2
1.5
1.5
1.5
1.5
MAX
5.2
5.2
6.2
6.2
5
5
UNIT
ns
ns
ns
OE
OE
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265