Crane Aerospace & Electronics Power Solutions
MTR Single, Dual and Triple DC/DC Converters
28 VOLT INPUT – 30 WATT
MTR SINGLE OUTPUT CONVERTER
1
+VIN
OUTPUT
COMMON
SENSE
RETURN
SENSE
INPUT
COMMON
POSITIVE
OUTPUT
4
1
3
6
1
RT
5
RL
10
EXTERNAL TRIM CONNECTION
1 Make connections at converter.
Trim Formulas
Vout = desired output voltage; Rt = trim resistor
3.3V: Rt = 1300 * Vout – 4304
1.2475
5V: Rt = 1300 * Vout – 6512
1.2475
12V: Rt = 1300 * Vout – 15631
1.2475
15V: Rt = 1300 * Vout – 19498
1.2475
F
IGURE
4: T
RIM
C
ONNECTION1, 2, 3
MTR SINGLE OUTPUT CONVERTER
1
+VIN
OUTPUT
COMMON
SENSE
RETURN
SENSE
INPUT
COMMON
POSITIVE
OUTPUT
4
2
3
6
2
RL
10
5
REMOTE SENSE CONNECTION
2 Make connections at load.
F
IGURE
5: R
EMOTE
S
ENSE
C
ONNECTION
Notes for Remote Sense and Trim
1. When trimming output voltage and/or remote sensing, the total output
voltage increase must be less than 0.6 volts at the converters pins to
maintain specified performance.
2. If neither voltage trim nor remote sense will be used, connect pin 3 to
pin 4 and pin 5 to pin 6 or the output voltage will increase by 1.2 volts.
3. CAUTION: The converter will be permanently damaged if the positive
remote sense (pin 6) is shorted to ground. Damage may also result if
the output common or positive output is disconnected from the load with
the remote sense leads connected to the load.
www.craneae.com
Page 4 of 19
Rev G - 20060505