欢迎访问ic37.com |
会员登录 免费注册
发布采购

EL100D5-05 参数 Datasheet PDF下载

EL100D5-05图片预览
型号: EL100D5-05
PDF下载: 下载PDF文件 查看货源
内容描述: 5A和10A 3-100 VDC评级 [Ratings of 5A and 10A 3-100 VDC]
分类和应用: 光电继电器固态继电器输出元件
文件页数/大小: 5 页 / 704 K
品牌: CRYDOM [ CRYDOM INC., ]
 浏览型号EL100D5-05的Datasheet PDF文件第2页浏览型号EL100D5-05的Datasheet PDF文件第3页浏览型号EL100D5-05的Datasheet PDF文件第4页浏览型号EL100D5-05的Datasheet PDF文件第5页  
EL Series
• Ratings of 5A and 10A @ 3-100 VDC
• UL Recognized, CE and RoHS Compliant
• 5, 12 and 24VDC control
• Mosfet Output
PRODUCT SELECTION
Control Voltage
4-8 VDC
10-14 VDC
21-27 VDC
5A
EL100D5-05
EL100D5-12
EL100D5-24
10A
EL100D10-05
EL100D10-12
EL100D10-24
OUTPUT SPECIFICATIONS (1)(3)
Description
Operating Voltage Range [VDC]
Maximum Load Current [Adc] (2)
Minimum Load Current [mAdc]
Transient Overvoltage [Vpk]
Maximum Surge Current Non-Repetitive (10ms) [A]
Maximum I² t for Fusing (50/60Hz, 1/2 cycle) [A² sec]
Maximum Off-State Leakage Current @ Rated Voltage [µAdc]
Maximum On-State Resistance @ Rated Current (Rds-on)
Maximum On-State Voltage Drop @ Rated Current
5A
3-100
5
150
600
115/120
65/60
100
0.04 Ohm
0.2V
10A
3-100
10
150
600
145/150
100/95
100
0.01 Ohm
0.1V
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Typical Input Current @ nominal turn-on voltage
Nominal Input Impedance [Ohms]
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [µsec]
EL100Dxx-05
4-8 VDC
4.0 VDC
0.5 VDC
13.3 mA
300
1
300
EL100Dxx-12
10-14 VDC
10 VDC
1.0 VDC
11.7 mA
940
1
300
EL100Dxx-24
21-27 VDC
21 VDC
2 VDC
11.5 mA
2K
1
300
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input to Output
Dielectric Strength, Output to Baseplate
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Terminals
Parameters
2500 Vrms
2500 Vrms
-30 to 80 °C
-30 to 125 °C
0.5 oz (14.4g)
3/16" input, 1/4" output QC
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) When mounted to the proper size heat sink (see derating curves)
3) Inductive loads should be diode suppressed to prevent damage to the relay.