欢迎访问ic37.com |
会员登录 免费注册
发布采购

EZE480D18 参数 Datasheet PDF下载

EZE480D18图片预览
型号: EZE480D18
PDF下载: 下载PDF文件 查看货源
内容描述: 全球专家固态继电器技术 [THE GLOBAL EXPERT IN SOLID STATE RELAY TECHNOLOGY]
分类和应用: 继电器固态继电器
文件页数/大小: 20 页 / 1264 K
品牌: CRYDOM [ CRYDOM INC., ]
 浏览型号EZE480D18的Datasheet PDF文件第5页浏览型号EZE480D18的Datasheet PDF文件第6页浏览型号EZE480D18的Datasheet PDF文件第7页浏览型号EZE480D18的Datasheet PDF文件第8页浏览型号EZE480D18的Datasheet PDF文件第10页浏览型号EZE480D18的Datasheet PDF文件第11页浏览型号EZE480D18的Datasheet PDF文件第12页浏览型号EZE480D18的Datasheet PDF文件第13页  
Panel Mount Solid State Relays - AC Output
CWD, CWA
10-125Amp
120/240/480/600 Vac
SCR AC Switch Output
Integrated IP20 Fingerproof Cover
EMC Compliant Design
The CW series offers a SCR AC switch output featuring low off-state leakage (1mA,
snubberless), zero cross or random turn-on (-10) switching and a wide operating
range (28-280Vrms) for optimum performance at 120V ac and 240Vac line voltages.
High thermal ratings with reduced power dissipation result in reduced heat sink
requirements for optimum performance. Additional features include; integrated,
removable finger-proof cover, LED status indication and user-friendly connectors. UL 508A
SCCR Approved, consult Crydom for actual ratings.
Line
Voltage
Range
Vrms
Load
Current
Range
Arms
Control
Voltage
Range
Vdc
Control
Current
@ 12Vdc
mA
Must
Release
Voltage
Vdc
Surge
Current
1-Cycle
Apk
H12
25-125Amp
480/600 Vac
SCR AC Switch Output
1200 Volt Blocking
High voltage relays use IC driven circuits for switching loads up to 660 VAC. All
models come with 1200 Volts blocking standard. Types CA, CD and WD are
snubberless and feature low off-state leakage. UL 508A SCCR Approved, consult
Crydom for actual ratings.
Line
Voltage
Range
Vrms
Load
Current
Range
Arms
Control
Voltage
Range
Vdc
Control
Current
@ 5Vdc
mA
Must
Release
Voltage
Vdc
Surge
Current
1-Cycle
Apk
CWD2410
CWD2425
CWD2450
CWD2490
CWD24125
CWD4810
CWD4825
CWD4850
CWD4890
CWD48125
24-280
24-280
24-280
24-280
24-280
48-660
48-660
48-660
48-660
48-660
Line
Voltage
Range
Vrms
.15-10
.15-25
.15-50
.25-90
.25-125
.15-10
.15-25
.15-50
.25-90
.25-125
Load
Current
Range
Arms
3-32
3-32
3-32
3-32
3-32
4-32
4-32
4-32
4-32
4-32
Control
Voltage
Range
Vrms
10
10
10
10
10
10
10
10
10
10
Control
Current
@120Vrms
mA
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Must
Release
Voltage
Vrms
400
600
850
1350
2000
400
600
850
1350
2000
Surge
Current
1-Cycle
Apk
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, cUL
H12WD4825
H12WD4850
H12WD4875
H12WD4890
H12WD48125
H12D4825
H12D4850
H12D4875
H12D4890
H12CD4825
H12CD4850
H12CD4890
48-660
48-660
48-660
48-660
48-660
48-530
48-530
48-530
48-530
48-660
48-660
48-660
Line
Voltage
Range
Vrms
.15-25
.15-50
.15-75
.15-90
.15-125
.15-25
.15-50
.15-75
.15-90
.15-25
.15-50
.15-90
Load
Current
Range
Arms
4-32
4-32
4-32
4-32
4-32
4-32
4-32
4-32
4-32
4-15
4-15
4-15
Control
Voltage
Range
Vrms
15
15
15
15
15
15
15
15
15
15
15
15
Control
Current
@120Vrms
mA
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Must
Release
Voltage
Vrms
250
625
1000
1200
1750
250
625
1000
1200
250
625
1200
Surge
Current
1-Cycle
Apk
UL, VDE
UL, CSA, VDE
VDE
UL, CSA, VDE
UL, cUL
UL, cUL, VDE
UL, CSA, VDE
VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
Panel Mount
CWA2410
CWA2425
CWA2450
CWA2490
CWA24125
CWA4810
CWA4825
CWA4850
CWA4890
CWA48125
24-280
24-280
24-280
24-280
24-280
48-660
48-660
48-660
48-660
48-660
.15-10
.15-25
.15-50
.25-90
.25-125
.15-10
.15-25
.15-50
.25-90
.25-125
90-280
90-280
90-280
90-280
90-280
90-280
90-280
90-280
90-280
90-280
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
400
600
850
1350
2000
400
600
850
1350
2000
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, cUL
H12CA4825
H12CA4850
H12CA4890
48-660
48-660
48-660
.15-25
.15-50
.15-90
90-140
90-140
90-140
15
15
15
10.0
10.0
10.0
250
625
1200
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
Random turn-on, phase controllable (-10 suffix)
HD, HA
12-125Amp
480Vac
Zero Voltage or Random Turn-on
Ultra Low Control Current
Operating Temperature Range: -40˚C to 80˚C , isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
24 Vac input versions available (E suffix)
SMR, SMR-6
25-90Amp
120/240/480 Vac
SCR AC Switch Output
Versatile System Monitoring SSR
LED Status Indicators, Alarm Output
The SMR system monitoring SSR’s offer a wide range of built-in fault condition
alarms to the end-user. Loss of voltage, open circuit load, relay damage and loss
of DC supply are constantly monitored. LED status indicators complete the
package for early detection of equipment problems. SMR-6 models offer the user
the capability to configure the relay with either inverting or non-inverting control
and alarm. The alarm circuit can sink or source up to 100mA.
Line
Voltage
Range
Vrms
Load
Current
Range
Arms
Control
Voltage
Range
Vdc
Control
Current
@ 12Vdc
mA
Alarm
Output
Current
mA
(max.)
Surge
Current
1-Cycle
Apk
Crydom's HD (DC control) and HA (AC control) relays incorporate the same
proven technologies as our Series 1. All models come with 1200 volts blocking as
standard and are available in either zero-cross or random turn-on and phase
controllable (-10) switching versions.
Line
Voltage
Range
Vrms
Load
Current
Range
Arms
Control
Voltage
Range
Vdc
Control
Current
@ 5Vdc
mA
Must
Release
Voltage
Vdc
Surge
Current
1-Cycle
Apk
HD4812
HD4825
HD4850
HD4875
HD4890
HD48110
HD48125
48-530
48-530
48-530
48-530
48-530
48-530
48-530
Line
Voltage
Range
Vrms
.04-12
.04-25
.04-50
.04-75
.04-90
.15-110
.15-125
Load
Current
Range
Arms
3-32
3-32
3-32
3-32
3-32
3-32
3-32
Control
Voltage
Range
Vrms
2.0
2.0
2.0
2.0
2.0
2.0
2.0
Control
Current
@120Vrms
mA
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Must
Release
Voltage
Vrms
140
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, cUL
UL, cUL
SMR2425
SMR2450
SMR2490
SMR2425-6
SMR2450-6
SMR2490-6
SMR4825-6
SMR4850-6
SMR4890-6
CSA, VDE
CSA, VDE
CSA, VDE
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
60-280
60-280
60-280
60-280
60-280
60-280
96-530
96-530
96-530
.04-25
.04-50
.04-90
.04-25
.04-50
.04-90
.04-25
.04-50
.04-90
8-32
8-32
8-32
8-32
8-32
8-32
8-32
8-32
8-32
6
6
6
6
6
6
6
6
6
100
100
100
100
100
100
100
100
100
250
625
1200
250
625
120
250
625
1200
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
HA4812
HA4825
HA4850
HA4875
HA4890
HA48110
HA48125
48-530
48-530
48-530
48-530
48-530
48-530
48-530
.04-12
.04-25
.04-50
.04-75
.04-90
.15-110
.15-125
90-280
90-280
90-280
90-280
90-280
90-280
90-280
2.0
2.0
2.0
2.0
2.0
2.0
2.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
Surge
Current
1-Cycle
Apk
140
UL, CSA, VDE
250
UL, CSA, VDE
625
UL, CSA, VDE
1000
UL, CSA, VDE
1200
UL, CSA, VDE
1500
UL, cUL
1750
UL, cUL
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
24 Vac input versions available (E suffix)
Other Crydom products and competitive part number cross-reference available at:
www.crydom.com
9