HRL 12500W
12V 500W
Specification
Cells per unit
Voltage per unit
Capacity
Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range
HRL 12500W is specially designed for high efficient discharge
application. Its characteristics are high energy density, small
footprint and high discharge efficiency. It can be used for more
than 260 cycles at 100% discharge in cycle service, up to 10
years in standby service.
6
12
o
o
500W @ 15min-rate to 1.67V per cell @25 C(77 F)
125 Ah @ 20hr-rate to 1.75V per cell @25
Approx.45.7 kg(100.75 lbs)
800A(5sec)
Approx.3.7
m
(77
)
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
25 C±3 C (77 F±5 F)
o
o
o
o
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging
Current Limit
Equalization and Cycle Service
Self Discharge
13.5 to 13.8 VDC/unit Average at 25
50A
(77 )
14.4 to 15.0 VDC/unit Average at 25
o
o
(77
)
CSB Batteries can be stored for more than 6 months at
25 C (77 F). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
CSB-manufactured
VRLA
batteries are UL-
recognized components
under UL924 and UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
Terminal
Container Material
I2-Thread lead alloy recessed terminal to accept M6 bolt
PPE(UL94-V0/File161759)*Flammability resistance can
be available upon request.
Dimensions :
Unit: mm (inch)
Overall Height (H)
277.7±2.5(10.93±0.1)
Container height (h)
274.7±2.5 (10.81±0.1)
Length (L)
343±2.5 (13.5±0.1)
Width (W)
170±2 (6.69±0.08)
Constant Current Discharge Characteristics
Unit:A (25
,77
)
F.V/Time
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
F.V/Time
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
5MIN
491
449
425
388
348
304
5MIN
5,275
4,880
4,640
4,250
3,830
3,366
7.5MIN
444
405
386
348
309
270
7.5MIN
4,691
4,300
4,110
3,750
3,340
2,882
10MIN
388
356
340
310
278
247
10MIN
4,167
3,790
3,610
3,290
2,950
2,600
15MIN
294
278
270
253
233
211
15MIN
3,181
3,018
2,932
2,748
2,497
2,203
20MIN
235
223
217
206
194
179
20MIN
2,594
2,490
2,422
2,309
2,138
1,964
30MIN
172
164
161
155
147
140
30MIN
1,951
1,871
1,829
1,740
1,657
1,564
40MIN
136
134
133
130
123
115
40MIN
1,558
1,520
1,507
1,466
1,390
1,321
50MIN
112
110
109
107
102
95.3
50MIN
1,292
1,276
1,258
1,237
1,186
1,130
60MIN
95.7
94.3
93.5
91.1
87.3
81.1
)
90MIN
67.2
66.1
65.4
64.5
62.0
57.3
90MIN
783
769
763
754
731
695
Constant Power Discharge Characteristics
Unit:W (25
,77
60MIN
1,112
1,091
1,083
1,066
1,025
977
RA0812