SC
Series
CHIP TYPE, LOW LEAKAGE CURRENT
Low leakage current (0.5 A to 2.0 A max.)
Low cost for replacement of many tantalum applications
Comply with the RoHS directive (2002/95/EC)
SPECIFICATIONS
Item
Operation Temperature Range
Rated Working Voltage
Capacitance Tolerance
Leakage Current
I
Characteristics
-40 ~ +85°C
6.3 ~ 50V
±20% at 120Hz, 20°C
0.002CV or 0.5 A whichever is greater (after 2 minutes)
I: Leakage current ( A)
C: Normal Capacitance ( F)
V: Rated Voltage (V)
Measurement frequency: 120Hz, Temperature: 20°C
Rate voltage (V)
6.3
10
16
25
35
50
Surge voltage (V)
8.0
13
20
32
44
63
tan (max.)
0.24
0.20
0.16
0.14
0.12
0.10
Rated voltage (V)
Impedance ratio
ZT/Z20 (max)
Capacitance Change
Dissipation Factor
Leakage Current
Z(-25°C) / Z(20°C)
Z(-40°C) / Z(20°C)
6.3
4
8
10
3
6
16
2
4
25
2
4
35
2
3
50
2
3
Dissipation Factor
Low
Temperature Characteristics
(Impedance radio at 120Hz)
Load Life
(After 2000 hours application of the
rated voltage at 85°C)
Within 20% of initial value
200% or less of initial specified value
initial specified value or less
After reflow soldering according to Reflow Soldering Condition (see page 8) and restored at
room temperature, they meet the characteristics requirements list as bellow.
Resistance to Soldering Heat
Capacitance Change
Dissipation Factor
Leakage Current
Reference Standard
Within 10% of initial value
initial specified value or less
initial specified value or less
JIS C-5141 and JIS C-5102
DRAWING (Unit: mm)
0.3max.
C 0.2
0.5Max.
A 0.2
E
A 0.2
Plastic platefom
Positive
0.5
L
+0.1
-0.2
B 0.2
D
Negative
0.5~0.8
DIMENSIONS (Unit: mm)
DxL
A
B
C
E
L
4 x 5.4
1.8
4.3
4.3
1.0
5.4
5 x 5.4
2.1
5.3
5.3
1.3
5.4
6.3 x 5.4
2.4
6.6
6.6
2.2
5.4
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com