Chokes for Data and Signal Lines
Double Chokes
General technical data
Rated voltage
V
R
Rated current
I
R
Rated inductance
L
R
42 Vac (50/60 Hz)
80 Vdc
B82790-C0***-N3
Referred to 50 Hz and 60
°C
ambient temperature
Measured with HP 4275A
at 10 kHz and 10 mV
(specified per winding)
– 30/+ 50 %
< 10 % at dc magnetic bias with
I
R
Measured at 10 kHz and 10 mV
Typical values, measured at 20
°C
ambient temperature
(215 3) ˚C, (3 0,3) s
wetting of soldering area
≥
95 %
in accordance with IEC 60068-2-58
40/125/56 (– 40
°C/+
125
°C/56
days damp heat test)
in accordance with IEC 60068-1
Approx. 2 g
Inductance tolerance
Inductance decrease
∆
L/L
0
Stray inductance
L
S
DC resistance
R
typ
Solderability
Climatic category
Weight
Characteristics and ordering codes
L
R
mH
4,7
6,8
10
22
33
50
L
S, typ
nH
500
500
600
800
1500
1700
I
R
mA
500
500
200
100
100
100
R
typ
Ω
0,4
0,5
1,1
1,6
2,0
2,6
V
T
Vdc, 2 s
1000
750
750
750
750
750
Ordering code
B82790-C0475-N340
B82790-C0685-N340
B82790-C0106-N340
B82790-C0226-N340
B82790-C0336-N365
B82790-C0506-N365
264
04/00