E
EMAOLII
Approved
Ericsson Internal
PRODUCT SPECIFICATION
No.
Checked
Date
1 (21)
Prepared (also subject responsible if other)
2/1301-BMR 454
Technical Specification
Uen
Rev
Reference
5
EN/LZT 146
404
R7A
March
2013
BMR454 series
SEC/D (Julia You)
Fully regulated Intermediate Bus Converters
F
SECSUND
2011-07-15
Input 36-75 V, Output up to
40
A / 240 W
© Ericsson AB
Absolute Maximum Ratings
Characteristics
T
P1
T
S
V
I
V
iso
V
tr
V
RC
V Logic I/O
Operating Temperature (see Thermal Consideration section)
Storage temperature
Input voltage
Isolation voltage (input to output test voltage), see note 1
Input voltage transient (Tp 100 ms)
Remote Control pin voltage
SALERT, CTRL, SYNC, SCL, SDA, SA(0,1)
-0.3
-0.3
min
-40
-55
-0.5
typ
max
+125
+125
80
1500
100
18
3.6
Unit
°C
°C
V
Vdc
V
V
V
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and
performance may degrade in an unspecified manner.
Note 1: Isolation voltage (input/output to base-plate) max 750 Vdc.
Fundamental Circuit Diagram
+IN
Driver
+OUT
-OUT
-IN
Auxillary
Supply
Driver
Control
RC
RC isolation