 浏览型号BMR4560004/004的Datasheet PDF文件第6页浏览型号BMR4560004/004的Datasheet PDF文件第7页浏览型号BMR4560004/004的Datasheet PDF文件第8页浏览型号BMR4560004/004的Datasheet PDF文件第9页浏览型号BMR4560004/004的Datasheet PDF文件第11页浏览型号BMR4560004/004的Datasheet PDF文件第12页浏览型号BMR4560004/004的Datasheet PDF文件第13页浏览型号BMR4560004/004的Datasheet PDF文件第14页  
E
10  
Technical Specification  
BMR456 series Fully regulated Advanced Bus Converters  
1/28701-FGC 101 1823 revD February 2013  
© Ericsson AB  
Input 36-75 V, Output up to 39 A / 468 W  
Typical Characteristics  
9.0 V, 35 A / 315 W  
BMR 456 0004/004  
Output Current Derating – Open frame  
[A]  
40  
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Output Current Derating – Base plate  
Thermal Resistance – Base plate  
[A]  
40  
[°C/W]  
6
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
5
4
3
2
1
0
2.0 m/s  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0[m/s]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Thermal resistance vs. airspeed measured at the converter. Tested in  
wind tunnel with airflow and test conditions as per the Thermal  
consideration section. VI = 53 V.  
Output Current Derating – Base plate + Heat sink  
Output Current Derating – Cold wall sealed box  
[A]  
35  
A
40  
35  
30  
3.0 m/s  
30  
2.0 m/s  
1.5 m/s  
25  
20  
15  
10  
5
25  
Tamb 8 5°C  
1.0 m/s  
0.5 m/s  
20  
15  
10  
5
Na t. Conv.  
0
0
0
20  
40  
60  
80  
100 [°C]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section. Tested with Plate Fin  
Transverse heatsink, height 0.23 In, P0114 Thermal Pad.  
Available load current vs. base plate temperature at 85ºC ambient.  
VI = 53 V. See Thermal Consideration section.