欢迎访问ic37.com |
会员登录 免费注册
发布采购

BMR457 参数 Datasheet PDF下载

BMR457图片预览
型号: BMR457
PDF下载: 下载PDF文件 查看货源
内容描述: 2012-07-27周2012年8月24日全面监管的高级总线转换器的输入36-75 V,输出高达25A / 300W的 [2012-07-27 Zhou 2012-08-24 Fully regulated Advanced Bus Converters Input 36-75 V, Output up to 25 A / 300 W]
分类和应用: 转换器
文件页数/大小: 36 页 / 2395 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号BMR457的Datasheet PDF文件第1页浏览型号BMR457的Datasheet PDF文件第2页浏览型号BMR457的Datasheet PDF文件第3页浏览型号BMR457的Datasheet PDF文件第5页浏览型号BMR457的Datasheet PDF文件第6页浏览型号BMR457的Datasheet PDF文件第7页浏览型号BMR457的Datasheet PDF文件第8页浏览型号BMR457的Datasheet PDF文件第9页  
E
EZHIXZH
Approved
Prepared (also subject responsible if other)
No.
Ericsson Internal
PRODUCT SPECIFICATION
Rev
Reference
4 (5)
BMR457 series
SEC/D (Julia You)
Fully
regulated Advanced
Bus
Converters
2012-07-27
Input 36-75 V, Output up to
25
A /
300
W
Safety Specification
General information
Ericsson Power Modules DC/DC converters and DC/DC
regulators are designed in accordance with the safety
standards IEC 60950-1, EN 60950-1 and UL 60950-1
Safety of Information Technology Equipment.
IEC/EN/UL 60950-1 contains requirements to prevent injury
or damage due to the following hazards:
Electrical shock
Energy hazards
Fire
Mechanical and heat hazards
Radiation hazards
Chemical hazards
Checked
1/1301- BMR 457 Uen
Technical Specification
Date
4
1/28701-FGC
101 1835
revC
August
2012
© Ericsson AB
B
circuit on the input source, this fuse will provide the
following functions:
Isolate the fault from the input power source so as not
to affect the operation of other parts of the system
Protect the distribution wiring from excessive current
and power loss thus preventing hazardous overheating
The DC/DC converter output is considered as safety extra
low voltage (SELV) if one of the following conditions is met:
The input source has double or reinforced insulation
from the AC mains according to IEC/EN/UL 60950-1
The input source has basic or supplementary insulation
from the AC mains and the input of the DC/DC
converter is maximum 60 Vdc and connected to
protective earth according to IEC/EN/UL 60950-1
The input source has basic or supplementary insulation
from the AC mains and the DC/DC converter output is
connected to protective earth according to
IEC/EN/UL 60950-1
Non - isolated DC/DC regulators
The DC/DC regulator output is SELV if the input source
meets the requirements for SELV circuits according to
IEC/EN/UL 60950-1.
On-board DC/DC converters and DC/DC regulators are
defined as component power supplies. As components
they cannot fully comply with the provisions of any safety
requirements without “conditions of acceptability”.
Clearance between conductors and between conductive
parts of the component power supply and conductors on
the board in the final product must meet the applicable
safety requirements. Certain conditions of acceptability
apply for component power supplies with limited stand-off
(see Mechanical Information for further information). It is
the responsibility of the installer to ensure that the final
product housing these components complies with the
requirements of all applicable safety standards and
regulations for the final product.
Component power supplies for general use should comply
with the requirements in IEC/EN/UL 60950-1
Safety of
Information Technology Equipment.
Product related
standards, e.g. IEEE 802.3af
Power over Ethernet,
and
ETS-300132-2
Power interface at the input to telecom
equipment, operated by direct current (dc)
are based on
IEC/EN/UL 60950-1 with regards to safety.
Ericsson Power Modules DC/DC converters and DC/DC
regulators are UL 60950-1 recognized and certified in
accordance with EN 60950-1. The flammability rating for all
construction parts of the products meet requirements for
V-0 class material according to IEC 60695-11-10,
Fire
hazard testing, test flames
– 50 W horizontal and vertical
flame test methods.
Isolated DC/DC converters
Galvanic isolation between input and output is verified in an
electric strength test and the isolation voltage (V
iso
) meets
the voltage strength requirement for basic insulation
according to IEC/EN/UL 60950-1.
It is recommended to use a slow blow fuse at the input of
each DC/DC converter. If an input filter is used in the circuit
the fuse should be placed in front of the input filter. In the
rare event of a component problem that imposes a short