PBA 3357/3  
Control Data  
Each channel of PBA 3357/3 has an ASIC which controls all line functions with a 8 bit serial word  
Relay  
Driver  
Test Relay Detector  
Gain  
Control  
SLIC Operation  
Receive  
Control  
Function  
Driver  
Select  
*
*
*
*
*
0
1
*
*
*
0
1
*
*
*
*
*
*
*
*
*
*
1
0
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
1
0
0
*
*
*
*
Receive Channel Off  
High Gain  
Low Gain  
Test relay driver  
Active (On)  
Test relay driver Inactive (Off)  
Relay driver Active (On)  
Relay driver Inactive (Off)  
Operating State  
Active Detector  
None  
*
*
*
*
X
X
*
*
0
0
0
0
0
1
*
*
Open Circiut  
Ring Relay driver  
Active (Ringing)  
Ring Trip  
*
*
*
*
0
1
*
*
1
1
1
1
0
0
1
1
1
1
0
0
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
0
1
1
*
*
Active  
Loop Current  
Ground Key  
Loop Current  
Ground Key  
Loop Current  
None  
Active  
*
*
0
*
*
Stand by  
Stand by  
Tip open  
No Function  
*
*
1
*
*
*
*
0
*
*
*
*
X
0
*
*
*
*
*
*
Active, Polarity Reversed Loop Current  
Active, Polarity Reversed Ground Key  
Stand by, Polarity Reversed Loop Current  
Stand by, Polarity Reversed Ground Key  
Sequence of Data Input (SDI)  
*
*
1
*
*
*
*
0
*
*
*
*
1
*
*
D7  
D6  
D5  
D4  
D3 D2 D1  
D0  
Comments: 1) X = Do not care 2) = Function specified elsewhere in the table.  
*
The CLIC will remain in its power-up state until programmed by sending the inverse of the desired command word  
followed by the desired command word. Example: To set CLIC in active state with command ’C8’, the inverse of  
’C8’, ’37’, followed by ’C8’ has to be sent. To set CLIC in standby state with command ’CA’, the inverse of ’CA’, ’35’,  
followed by ’CA’ has to be sent. Once this has been done the CLIC is enabled to take single-word command. The  
Power-up state is Open Circuit and no Relay Driver activated.  
Example on Control Input:  
HEX Word  
Binary Word  
Function  
D7 D6 D5 D4 D3 D2 D1 D0  
Relay Driver Off  
Testrelay Driver Off  
(Bit D7 )  
(Bit D6 )  
C8  
1
1
0
0
1
0
0
0
C
8
Active, Detector = Loop Current (Bit D3, D2, D1 and D5)  
Receive Channel On, Low Gain (Bit D0 and D4 )  
D7 D6 D5 D4 D3 D2 D1 D0  
Relay Driver Off  
(Bit D7 )  
D2  
1
1
0
1
0
0
1
0
Testrelay Driver Off  
(Bit D6 )  
D
2
Ringing, Detector = Ring Trip  
Receive Channel On, High Gain  
(Bit D3, D2, D1)  
(Bit D0 and D4 )  
Note: BIT D7 is sent first, BIT D0 is sent last.  