PBL 386 40/2
Maximum Ratings
Parameter
Symbol
Min
Max
Unit
Temperature, Humidity
Storage temperature range
Operating temperature range
Operating junction temperature range, Note 1
Power supply,
-40°C
≤
T
Amb
≤
+85°C
V
CC
with respect to A/BGND
V
Bat2
with respect to A/BGND
V
Bat
with respect to A/BGND, continuous
V
Bat
with respect to A/BGND, 10 ms
Power dissipation
Continuous power dissipation at T
Amb
≤
+85
°C
Ground
Voltage between AGND and BGND
Relay Driver
Ring relay supply voltage
Ring trip comparator
Input voltage
Input current
Digital inputs, outputs
(C1, C2, C3, DET)
Input voltage
Output voltage
TIPX and RINGX terminals,
-40°C < T
Amb
< +85°C, V
Bat
= -50V
Maximum supplied TIPX or RINGX current
TIPX or RINGX voltage, continuous (referenced to AGND), Note 2
TIPX or RINGX, pulse < 10 ms, t
Rep
> 10 s, Note 2
TIPX or RINGX, pulse < 1
µs,
t
Rep
> 10 s, Note 2
TIPX or RINGX, pulse < 250 ns, t
Rep
> 10 s, Notes 2 & 3
T
Stg
T
Amb
T
J
V
CC
V
Bat2
V
Bat
V
Bat
P
D
V
G
-55
-40
-40
-0.4
V
Bat
-75
-80
+150
+110
+140
6.5
0.4
0.4
0.4
1.5
°C
°C
°C
V
V
V
V
W
V
-0.3
+0.3
BGND+14 V
V
DT
, V
DR
I
DT
, I
DR
V
ID
V
OD
I
TIPX
, I
RINGX
V
TA
, V
RA
V
TA
, V
RA
V
TA
, V
RA
V
TA
, V
RA
V
Bat
-5
-0.4
-0.4
AGND
5
V
CC
V
CC
+100
2
5
10
15
V
mA
V
V
-100
-80
V
Bat
-10
V
Bat
-25
V
Bat
-35
mA
V
V
V
V
Recommended Operating Condition
Parameter
Symbol
Min
Max
Unit
Ambient temperature
V
CC
with respect to AGND
V
Bat
with respect to AGND
AGND with respect to BGND
T
Amb
V
CC
V
Bat
V
G
-40
4.75
-58
-100
+85
5.25
-8
100
°C
V
V
mV
Notes
1.
2.
3.
The circuit includes thermal protection. Operation at or above 140°C junction temperature may degrade device reliability.
With the diodes D
VB
and D
VB2
included, see figure 12.
R
F1
and R
F2
≥
20
Ω
is also required. Pulse is applied to TIP and RING outside R
F1
and R
F2
.
2