欢迎访问ic37.com |
会员登录 免费注册
发布采购

PKB4204BPIPHSM/B 参数 Datasheet PDF下载

PKB4204BPIPHSM/B图片预览
型号: PKB4204BPIPHSM/B
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Regulated Power Supply Module, 1 Output, 243W, Hybrid, ROHS COMPLIANT PACKAGE-5]
分类和应用:
文件页数/大小: 26 页 / 727 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号PKB4204BPIPHSM/B的Datasheet PDF文件第1页浏览型号PKB4204BPIPHSM/B的Datasheet PDF文件第2页浏览型号PKB4204BPIPHSM/B的Datasheet PDF文件第4页浏览型号PKB4204BPIPHSM/B的Datasheet PDF文件第5页浏览型号PKB4204BPIPHSM/B的Datasheet PDF文件第6页浏览型号PKB4204BPIPHSM/B的Datasheet PDF文件第7页浏览型号PKB4204BPIPHSM/B的Datasheet PDF文件第8页浏览型号PKB4204BPIPHSM/B的Datasheet PDF文件第9页  
E
Approved
Ericsson Internal
PRODUCT SPECIFICATION
No.
3 (4)
Prepared (also subject responsible if other)
SEC/S Marshall Wang
Checked
BPOW 00201-1/1301 Uen
Date
Rev
Technical Specification
Reference
May
2013
© Ericsson AB
3
PKB 4000B series
Intermediate Bus Converters
2013-02-07
Input 36-75 V, Output up to
40
A / 252 W
Safety Specification
General information
Ericsson Power Modules DC/DC converters and DC/DC
regulators are designed in accordance with the safety
standards IEC 60950-1, EN 60950-1 and UL 60950-1
Safety of Information Technology Equipment.
IEC/EN/UL 60950-1 contains requirements to prevent injury
or damage due to the following hazards:
Electrical shock
Energy hazards
Fire
Mechanical and heat hazards
Radiation hazards
Chemical hazards
EN/LZT 146
384
R4A
B
Z
one of the following conditions is met:
The input source provides supplementary or double or
reinforced insulation from the AC mains according to
IEC/EN/UL 60950-1.
The input source provides functional or basic insulation
from the AC mains and the product’s output is reliably
connected to protective earth according to
IEC/EN/UL 60950-1.
For functional insulated products (see Safety Certificate)
the output is considered as safety extra low voltage (SELV)
if one of the following conditions is met:
The input source provides double or reinforced
insulation from the AC mains according to
IEC/EN/UL 60950-1.
The input source provides basic or supplementary
insulation from the AC mains and the product’s output is
reliably connected to protective earth according to
IEC/EN/UL 60950-1.
The input source is reliably connected to protective
earth and provides basic or supplementary insulation
according to IEC/EN/UL 60950-1 and the maximum
input source voltage is 60 Vdc.
On-board DC/DC converters and DC/DC regulators are
defined as component power supplies. As components
they cannot fully comply with the provisions of any safety
requirements without “conditions of acceptability”.
Clearance between conductors and between conductive
parts of the component power supply and conductors on
the board in the final product must meet the applicable
safety requirements. Certain conditions of acceptability
apply for component power supplies with limited stand-off
(see Mechanical Information and Safety Certificate for
further information). It is the responsibility of the installer to
ensure that the final product housing these components
complies with the requirements of all applicable safety
standards and regulations for the final product.
Component power supplies for general use should comply
with the requirements in IEC/EN/UL 60950-1
Safety of
Information Technology Equipment.
Product related
standards, e.g. IEEE 802.3af
Power over Ethernet,
and
ETS-300132-2
Power interface at the input to telecom
equipment, operated by direct current (dc)
are based on
IEC/EN/UL 60950-1 with regards to safety.
Ericsson Power Modules DC/DC converters, Power
interface modules and DC/DC regulators are UL 60950-1
recognized and certified in accordance with EN 60950-1.
The flammability rating for all construction parts of the
products meet requirements for V-0 class material
according to IEC 60695-11-10,
Fire hazard testing, test
flames
– 50 W horizontal and vertical flame test methods.
Isolated DC/DC converters & Power interface modules
The product may provide basic or functional insulation
between input and output according to IEC/EN/UL 60950-1
(see Safety Certificate), different conditions shall be met if
the output of a basic or a functional insulated product shall
be considered as safety extra low voltage (SELV).
Galvanic isolation between input and output is verified in an
electric strength test and the isolation voltage (V
iso
) meets
the voltage strength requirement for basic insulation
according to IEC/EN/UL 60950-1.
It is recommended to use a slow blow fuse at the input of
each DC/DC converter. If an input filter is used in the circuit
the fuse should be placed in front of the input filter. In the
rare event of a component problem that imposes a short
circuit on the input source, this fuse will provide the
following functions:
Isolate the fault from the input power source so as not
to affect the operation of other parts of the system
Protect the distribution wiring from excessive current
and power loss thus preventing hazardous overheating
Non - isolated DC/DC regulators
The DC/DC regulator output is SELV if the input source
meets the requirements for SELV circuits according to
IEC/EN/UL 60950-1.
For basic insulated products (see Safety Certificate) the
output is considered as safety extra low voltage (SELV) if