E
Technical Specification
PKB 4000A series
Direct Converters
Input 36-72 V, Output up to 30 A /
125
W
Absolute Maximum Ratings
Characteristics
T
P1
T
S
V
I
V
iso
V
tr
V
RC
V
adj
Operating Temperature (see Thermal Consideration section)
Storage temperature
Input voltage
Isolation voltage (input to output test voltage)
Input voltage transient (t
p
100 ms)
Remote Control pin voltage
(see Operating Information section)
Adjust pin voltage (see Operating Information section)
Positive logic option
Negative logic option
0
0
-0.5
4
EN/LZT 146
420
R3A
March
2014
© Ericsson AB
min
-40
-55
-0.5
typ
max
+125
+110
+80
2250
100
40
40
2xV
oi
Unit
°C
°C
V
Vdc
V
V
V
V
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits in the Electrical Specification. If exposed to stress above these limits, function and performance
may degrade in an unspecified manner.
Fundamental Circuit Diagram
+ In
Primary
Secondary
+ Out
+ Sense
Primary
Driver
Secondary
Driver
- Sense
- Out
Bias supply
and OTP
RC
Isolated
Feedback
Control and
Supervision
Vadj
- In