 浏览型号PKF2113API/A的Datasheet PDF文件第8页浏览型号PKF2113API/A的Datasheet PDF文件第9页浏览型号PKF2113API/A的Datasheet PDF文件第10页浏览型号PKF2113API/A的Datasheet PDF文件第11页浏览型号PKF2113API/A的Datasheet PDF文件第13页浏览型号PKF2113API/A的Datasheet PDF文件第14页浏览型号PKF2113API/A的Datasheet PDF文件第15页浏览型号PKF2113API/A的Datasheet PDF文件第16页  
Radiated EMS (Electro-Magnetic Fields )  
EMC Specifications  
Radiated EMS is measured according to test methods in  
IEC Standard publ. 801-3. No deviation outside the VO tolerance  
band will occur under the following conditions:  
The fundamental switching frequency is 510 kHz ±10 kHz.  
Frequency range  
0.01...200 MHz  
200...1,000 MHz 3 Vrms/m  
Voltage level  
3 Vrms/m  
Conducted EMI (input teminals )  
1...12 GHz  
10 Vrms/m  
ESD  
Electro Static Discharge is tested according to IEC publ. 801-2. No  
destruction will occur if the following voltage levels are applied to  
any of the terminal pins:  
Test  
Air discharge  
Voltage level  
±4 kV  
Contact discharge ±2 kV  
EFT  
Electrical Fast Transients on the input terminals could affect the out-  
put voltage regulation causing functional errors on the Printed Board  
Assembly (PBA). The PKF power module withstand EFT levels of  
0.5 kV keeping VO within the tolerance band and  
2.0 kV without destruction. Tested according to IEC publ. 801-4.  
Output Ripple & Nois e (VOac)  
PKF series typical conducted EMI performance  
Output ripple is measured as the peak to peak voltage of the funda-  
mental switching frequency.  
Tes t s et up  
The PKF meets class A in VDE 0871/0878, FCC Part 15J, and CISPR 22  
(EN 55022), except for the fundamental switching frequency.  
Radiated EMI  
Radiated emission of electromagnetic fields is measured at 10 m  
distance.  
30...100 MHz  
100...200 MHz  
200...230 MHz  
60 dB V/m  
40 dB V/m  
30 dB V/m  
230...1,000 MHz 35 dB V/m  
1...10 GHz 46 dB V/m  
Conducted EMS  
Electro Magnetic Susceptibility is measured by injection of  
electrical disturbances on the input terminals. No deviation  
outside the VO tolerance band will occur under the following  
conditions:  
Frequency range  
0.15...300 MHz  
Voltage level  
1.0 Vrms  
The signal is amplitude modulated with 1 kHz/80% and applied in  
differential and common mode.  
12  