欢迎访问ic37.com |
会员登录 免费注册
发布采购

PKF4221ASI 参数 Datasheet PDF下载

PKF4221ASI图片预览
型号: PKF4221ASI
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Regulated Power Supply Module, 2 Output, 15W, Hybrid]
分类和应用: 输入元件输出元件
文件页数/大小: 8 页 / 252 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号PKF4221ASI的Datasheet PDF文件第1页浏览型号PKF4221ASI的Datasheet PDF文件第2页浏览型号PKF4221ASI的Datasheet PDF文件第3页浏览型号PKF4221ASI的Datasheet PDF文件第4页浏览型号PKF4221ASI的Datasheet PDF文件第5页浏览型号PKF4221ASI的Datasheet PDF文件第7页浏览型号PKF4221ASI的Datasheet PDF文件第8页  
Radiated EMS (Electro-Magnetic Fields)
Radiated EMS is measured according to test methods in
IEC Standard publ. 801-3. No deviation outside the V
O
tolerance band will occur under the following conditions:
Frequency range
Voltage level
0.01...200 MHz
3 V
rms
/m
200...1,000 MHz
3 V
rms
/m
1...12 GHz
10 V
rms
/m
Conducted EMS
Electro Magnetic Susceptibility is measured by injection of
electrical disturbances on the input terminals. No deviation
outside the V
O
tolerance band will occur under the following
conditions:
Frequency range
Voltage level
30...300 MHz
1.0 V
rms
The signal is amplitude modulated with 1 kHz/80% and
applied in both differential and common mode.
ESD
Electro Static Discharge is tested according to IEC publ. 801-
2. No destruction will occur if the following voltage levels are
applied to any of the terminal pins:
Test
Air discharge
Contact discharge
Voltage level
±4 kV
±2 kV
Operating Information
Fuse Considerations
To prevent excessive current from flowing through the input
supply line, in the case of a short-circuit across the converter
input, an external fuse should be installed in the non-earthed
input supply line. We recommend using a fuse rated at
approximately 2 to 4 times the value calculated in the formula
below:
I
inmax
=
P
O max
min
× V
I min
)
Refer to the fuse manufacturer for further information.
Remote Control (RC)
Turn-on or turn-off can be realized by using the RC-pin. If pin
11 is connected to pin 17 the power modules turns off. Normal
operation is achieved if pin 11 is open (NC). To ensure safe
turn-off the voltage difference between pin 11 and 17 shall be
less than 1.0 V. RC is an open collector compatible input. A
sink capacity of 1mA is needed. (see fig. 1).
PKF 4221A
EFT
Electrical Fast Transients on the input terminals could affect
the output voltage regulation causing functional errors on
the Printed Board Assembly (PBA). The PKF power modules
withstand EFT levels of 0.5 kV keeping V
O
within the
tolerance band and
2.0 kV without destruction. Tested according to IEC publ.
801-4.
Output Ripple & Noise (V
O
ac)
Output ripple is measured as the peak to peak voltage of the
fundamental switching frequency.
Figure 1
Turn-on/off Input Voltage
The power module monitors the input voltage and will turn on
and turn off at predetermined levels set by means of external
resistors.
To increase V
Ion
a resistor should be connected between pin
11 and 17 (see fig. 2).
The resistance is given by the following equation:
For V
I
>34.5V,
R
innom
=(2510-V
I
)/(V
I
-34.5) kΩ
V
I
is the desired turn-on input voltage. The values are nominal
and apply when the unadjusted module turns on at 34.5V.
To decrease V
Ion
a resistor should be connected between pin
10 and 11 (see fig. 3). The resistance is given by the following
equation:
For 30.5<V
I
<34.5 V,
R
innom
=55×(V
I
-30.5)/(34.5-V
I
) kΩ
V
I
is the desired turn-on input voltage. The values are nominal
and apply when the unadjusted module turns on at 34.5V.
6