DC Electrical Characteristics (Continued)
VCC
T
A = +25°C
TA = −40°C to +85°C
Symbol
VOL
Parameter
Units
Conditions
(V)
1.65
1.8
Min
Typ
0.0
Max
0.1
0.1
0.1
0.1
0.1
0.24
0.3
0.4
0.55
0.55
±0.1
1
Min
Max
0.1
LOW Level Output
Voltage
0.0
0.1
2.3
0.0
0.1
I
OL = 100 µA
3.0
0.0
0.1
4.5
0.0
0.1
V
V
IN = VIL
1.65
2.3
0.08
0.10
0.16
0.24
0.25
0.24
0.3
IOL
IOL
=
=
4 mA
8 mA
3.0
0.4
I
I
I
OL = 16 mA
3.0
0.55
0.55
±1.0
10
OL = 24 mA
OL = 32 mA
4.5
IIN
Input Leakage Current
0 to 5.5
0.0
µA
V
IN = 5.5V, GND
IOFF
ICC
Power Off Leakage Current
µA VIN or VOUT = 5.5V
Quiescent Supply Current 1.65 to 5.5
1.0
10
µA
V
IN = 5.5V, GND
AC Electrical Characteristics
VCC
T
A = +25°C
TA = −40°C to +85°C
Figure
Symbol
Parameter
Units
Conditions
(V)
1.65
Min
Typ
8.3
6.9
4.8
3.7
3.0
4.3
3.6
2.5
10
Max
Min
2.0
2.0
1.5
1.0
0.8
1.5
1.0
Max
15.8
13.1
9.0
Number
tPLH
tPHL
Propagation Delay
2.0
2.0
1.5
1.0
0.8
1.5
1.0
14.3
11.9
8.2
1.8
C
L = 15 pF,
L = 1 MΩ
Figures
1, 3
2.5 ± 0.2
3.3 ± 0.3
5.0 ± 0.5
3.3 ± 0.3
5.0 ± 0.5
0
ns
R
5.6
6.2
4.7
5.2
tPLH
tPHL
CIN
Propagation Delay
6.6
7.3
C
L = 50 pF,
L = 500Ω
Figures
1, 3
ns
pF
pF
5.6
6.2
R
Input Capacitance
Power Dissipation
Capacitance
CPD
3.3
(Note 3)
Figure 2
5.0
12
Note 3: CPD is defined as the value of the internal equivalent capacitance which is derived from dynamic operating current consumption (ICCD) at no output
loading and operating at 50% duty cycle. (See Figure 2.) CPD is related to ICCD dynamic operating current by the expression:
ICCD = (CPD)(VCC)(fIN) + (ICCstatic).
AC Loading and Waveforms
CL includes load and stray capacitance
Input PRR = 1.0 MHz; tW = 500 ns
FIGURE 1. AC Test Circuit
Input = AC Waveform; tr = tf = 1.8 ns;
PRR = variable; Duty Cycle = 50%
FIGURE 3. AC Waveforms
FIGURE 2. ICCD Test Circuit
3
www.fairchildsemi.com