FUNCTIONAL DEVICE OPERATION  
OPERATIONAL MODES  
Table 7. Wake-up/Interrupt Command  
Wake-up/Interrupt Command  
Command Bits  
23 22 21 20 19 18 17 16 15 14  
13  
X
12  
X
11  
X
10  
X
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
1
X
X
X
X
X
X
sp7 sp6 sp5 sp4 sp3 sp2 sp1 sp0  
sg13 sg12 sg11 sg10 sg9 sg8 sg7 sg6 sg5 sg4 sg3 sg2 sg1 sg0  
WETTING CURRENT REGISTER  
The 33972 has two levels of switch contact current, 16mA  
and 2.0mA (see Figure 11). The metallic command is used to  
set the switch contact current level (Table 8). Programming  
the metallic bit to logic [0] will set the switch wetting current to  
2.0mA. Programming the metallic bit to logic [1] will set the  
switch contact wetting current to 16mA. The MCU may  
change or update the wetting current register via software at  
any time in Normal Mode.  
Switch Contact Voltage  
16 mA Switch Wetting Current  
Wetting current is designed to provide higher levels of  
current during switch closure. The higher level of current is  
designed to keep switch contacts from building up oxides that  
form on the switch contact surface.  
2.0 mA Switch Sustain Current  
20 ms Wetting Current Timer  
Figure 11. Contact Wetting and Sustain Current  
Table 8. Metallic Command  
Metallic Command  
Command Bits  
23 22 21 20 19 18 17 16 15 14  
13  
X
12  
X
11  
X
10  
X
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
1
X
X
X
X
X
X
sp7 sp6 sp5 sp4 sp3 sp2 sp1 sp0  
sg13 sg12 sg11 sg10 sg9 sg8 sg7 sg6 sg5 sg4 sg3 sg2 sg1 sg0  
closed switch contact. With multiple wetting current timers  
disabled, power dissipation for the IC must be considered.  
WETTING CURRENT TIMER REGISTER  
The MCU may change or update the wetting current timer  
Each switch input has a designated 20ms timer. The timer  
starts when the specific switch input crosses the comparator  
threshold (4.0V). When the 20ms timer expires, the contact  
current is reduced from 16mA to 2.0mA. The wetting current  
timer may be disabled for a specific input. When the timer is  
disabled, 16mA of current will continue to flow through the  
register via software at any time in Normal Mode. This allows  
the MCU to control the amount of time wetting current is  
applied to the switch contact. Programming the wetting  
current timer bit to logic [0] will disable the wetting current  
timer. Programming the wetting current timer bit to logic [1]  
will enable the wetting current timer (Table 9).  
Table 9. Wetting Current Timer Enable Command  
Wetting Current Timer Commands  
Command Bits  
23 22 21 20 19 18 17 16 15 14  
13  
X
12  
X
11  
X
10  
X
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
1
1
0
1
0
1
0
X
X
X
X
X
X
sp7 sp6 sp5 sp4 sp3 sp2 sp1 sp0  
sg13 sg12 sg11 sg10 sg9 sg8 sg7 sg6 sg5 sg4 sg3 sg2 sg1 sg0  
33972  
Analog Integrated Circuit Device Data  
Freescale Semiconductor  