欢迎访问ic37.com |
会员登录 免费注册
发布采购

A175126RRPG08 参数 Datasheet PDF下载

A175126RRPG08图片预览
型号: A175126RRPG08
PDF下载: 下载PDF文件 查看货源
内容描述: [Optoelectronic Device]
分类和应用:
文件页数/大小: 10 页 / 88 K
品牌: FUJITSU [ FUJITSU ]
 浏览型号A175126RRPG08的Datasheet PDF文件第1页浏览型号A175126RRPG08的Datasheet PDF文件第3页浏览型号A175126RRPG08的Datasheet PDF文件第4页浏览型号A175126RRPG08的Datasheet PDF文件第5页浏览型号A175126RRPG08的Datasheet PDF文件第6页浏览型号A175126RRPG08的Datasheet PDF文件第7页浏览型号A175126RRPG08的Datasheet PDF文件第8页浏览型号A175126RRPG08的Datasheet PDF文件第9页  
A1751A DWDM Analog  
Forward-Path or Return-Path Laser Modules  
Data Sheet, Rev. 4  
June 2001  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-  
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess  
of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended  
periods can adversely affect device reliability.  
Parameter*  
Symbol  
Min  
Max  
Unit  
Operating Case Temperature Range  
Storage Temperature Range  
Monitor Photodiode Reverse Voltage  
Laser Forward Current  
TC  
Tstg  
VMPD  
IF  
–40  
–40  
85  
85  
10  
150  
2
°C  
°C  
V
mA  
V
Reverse Voltage (Laser)  
TEC Current  
VR  
ITEC  
PRFIN  
1.7  
62  
A
RF Input Power  
dBm V  
* The device can withstand continuous exposure to the specified limits without damage.  
Characteristics  
Table 1. Key Characteristics  
Parameter  
Symbol  
Conditions  
Min  
Typ  
Max  
Unit  
Frequency Range:1  
Return Path  
F
MHz  
MHz  
MHz  
5
40  
210  
860  
Forward Path  
Frequency Response:1  
5 MHz—210 MHz  
IF = 60 mA,  
TOP = 25 °C  
±0.5  
±0.5  
dB  
dB  
40 MHz—860 MHz  
RF Return Loss:1  
5 MHz—210 MHz  
40 MHz—860 MHz  
RLRF  
IF = 60 mA,  
IF = IOP  
>16  
>16  
dB  
dB  
Optical Output Power  
PO  
6, 8, or  
10  
mW  
Laser Relative Intensity  
Noise  
RIN  
IF = ITH + 70 mA,  
T = 25 °C  
< –155  
dB/Hz  
Composite Second Order2, 3  
Composite Triple Beat2, 4  
Available Wavelengths  
Wavelength Drift5  
CSO  
CTB  
λ
IF = IOP, OMI = 10%  
IF = IOP, OMI = 10%  
IP = IOP, T = TOP  
–50  
–60  
dBc  
dBc  
nm  
1527.94  
1563.1  
0.04  
λ∆  
IF = 60 mA,  
T = TOP,  
nm  
TC varied from min—>max  
Adiabatic Chirp  
FM  
TC  
IF = 60 mA,  
TOP = 25 °C,  
measured at 500 MHz  
40  
100  
85  
MHz/mA  
Operating Case  
IF = IOP  
–40  
°C  
Temperature Range  
1. Tested in a 50 resistively matched system.  
2. Eight channel loading with 10% OMI and 40 km fiber length.  
3. Measured at 42 MHz.  
4. Measured at 553.25 MHz, 577.25 MHz, and 595.25 MHz.  
5. Change in wavelength as case temperature is changed.  
2
Agere Systems Inc.