欢迎访问ic37.com |
会员登录 免费注册
发布采购

600-090 参数 Datasheet PDF下载

600-090图片预览
型号: 600-090
PDF下载: 下载PDF文件 查看货源
内容描述: 811系列Mighty Mouse鼠标高密度( HD)联系人和工具带法师?先进的终端系统带和说明 [Series 811 Mighty Mouse High Density (HD) Contacts and Tools Band-Master? Advanced Termination System Bands and instructions]
分类和应用:
文件页数/大小: 1 页 / 263 K
品牌: GLENAIR [ GLENAIR, INC. ]
   
band-Master™ Advanced Termination System
bands and instructions
glenair Band-Master™ Advanced Termination System: How To Order
1
Fast, cost-effective shield termination. Attach cable shields to backshells with
Band-Master™ ATS
stainless
steel straps. The
Band-Master™ ATS
system offers fast termination and the flexibility to handle a wide range
of parts with just one band size. Approved for aerospace and defense, these straps have successfully passed
rigorous shock, vibration and environmental testing.
Band installation Tool. Use with .240" (6.10 mm)
wide bands. 6.75 inches (172 mm) length, 1.2
pounds (0.6 Kg.)
1
2
Standard Band, .240" (6.10 mm) wide. Available
in two lengths, flat or pre-coiled. Stainless steel.
Figure
1
Description
Band installation Tool
Length
in.
mm
14.250 362.1
18.000 457.2
Part Number
600-058
Accommodates Diameter
in.
mm
1.8
45.7
2.5
63.5
Figure
2
2
Part Number
Flat
Pre-Coiled
600-052
600-052-1
600-090
600-090-1
2
Contact Glenair or visit our website (glenair.com) to view our complete line of
Band-Master™ ATS
products,
including pneumatic tools for high volume production and calibration kits.
LENGTH ± .060 (1.5)
.240 (6.10)
.350 (8.9)
TAIL LENGTH
INDICA OR MARK
OR MARK
T
Adapter
Retention Lip
Conductors
Braid
.400 (1.2mm) Min.
Length Braid Over
Termination Area
Band-Master™ ATS Shield Termination instructions
1.
Prepare Cable Braid for termination process
(Figure 1).
2.
Push Braid forward over Adapter Retention Lip
to the Adapter incline Point (or .4" [10.2mm]
minimum braid length). Milk Braid as required
to remove slack and insure a snug fit around
the shield termination area (Figure 2).
3.
Prepare the Band in the following manner:
IMPORTANT: Due to Connector/Adapter cir-
cumference, it may be necessary to prepare
the Band around the Cable or Retention Area.
A. Roll Band through the Buckle Slot twice.
(Bands must be double-coiled.)
B. Pull on Band until Mark ( ) is within ap-
proximately .250 inch (6.4mm) of Buckle
Slot (Figure 3). The Band may be tightened
further if desired.
NOTE:
Prepared Band should have ( ) Mark
visible approximately where shown in Figure
3.
Shield Termination
Clamping Process (Figures 4 thru 8)
NOTE:
To free Tool Handles, move Holding Clips
to center of Tool.
4.
Squeeze Gripper Release Lever and insert
Band into the front end opening of the
Tool. (NOTE: Circular portion of looped
band must always face downward.)
5.
Aligning the Band and Tool with the Shield
Termination Area, squeeze Black Pull-Up
Handle repeatedly using short strokes until
it locks against Tool Body. (This indicates
the Band is compressed to the Tool Preca-
librated Tension.)
NOTE: If alignment of band and shield is
unsatisfactory, tension on band can be
relaxed by pushing on slotted release
lever on top of tool. Make adjustments as
necessary and again squeeze black pull-up
handle.
6.
Complete the Clamping Process by squeez-
ing the Gray Cut-Off Handle.
7.
Remove excess band from tool and dispose.
8.
inspect Shield Termination.
1
Adapter
incline
2
Buckle
3
Tail Length
indicator Mark
4
5
6
7
8
Dimensions in Inches (millimeters) are subject to change without notice.
© 2011 Glenair, Inc.
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
29
E-Mail: sales@glenair.com
Mighty Mouse
High Density
Series 811 Mighty Mouse High Density (HD)
Contacts and Tools