AT1308
Micro-Power Step up DC-DC Converter
Absolute Maximum Ratings
*
1
Parameter
VIN voltage
LX voltage
EN , FB to GND
Switch Current (I
LX
)
Continuous power dissipation (SOT-25 Ta=+25 C)
Operating Junction Temperature Range
Lead Temperature (Soldering 5 sec)
Storage Temperature
Package Thermal Resistance (Θ
JA
)
ESD Susceptibility*
2
HBM
MM
O
Rated Value
-0.3 to +6.5
-0.3 to +30
-0.3 to +6.5
0.6
0.25
-30 to 85
260
-65 to 125
250
2
200
Unit
V
V
V
A
W
℃
℃
℃
℃/W
KV
V
1. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the
device. These are stress ratings only, and functional operation of the device at these or any other
conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure
to absolute maximum rating conditions for extended periods may affect device reliability
.
2. Device are ESD sensitive. Handling precaution recommended. The Human Body model is a 100pF
capacitor discharged through a 1.5KΩ resistor into each pin.
Recommended Operation Conditions
Parameter
Power supply voltage
Operating temperature
Symbol
Min.
V
IN
Top
2.5
-20
Values
Typ.
―
+25
Max.
6.0
+85
Unit
V
℃
7F, No.9, PARK AVENUE II, Science-Based Industrial Park, Hsinchu 300,Taiwan, R.O.C.
Tel: 886-3-563-0878
Fax: 886-3-563-0879
WWW:
http://www.aimtron.com.tw
12/15/2006 REV:1.2
Email:
service@aimtron.com.tw
3