Hazardous Location
3/4 INCH EXPLOSION-PROOF SENSORS (All dimensions for reference only. mm/[in])
When properly installed using the explosion containment method, all 3070X and catalog listings on this page are certified for use in
hazardous locations as follows: Class I, Groups A, B, C, D; Class II Groups E, F, G; Class III.
These catalog listings have been tested to and meet the requirements of applicable U.S. and Canadian specifications for the
locations described above.
General Specifications
Parameter
Characteristic
Min. output voltage 60 Vp-p
Coil resistance
Pole piece
diameter
Min. surface
speed
Operating temp.
range
Mounting thread
191 Ohm to 280 Ohm
4,75 mm [0.187 in]
0,38 m/s [15 in/s] typ.
-73
ºC
to 93
ºC
[-100
ºF
to 200
ºF]
3/4-20 UNEF-2A
Parameter
Inductance
Gear pitch range
Optimum actuator
Max. operating
frequency
Vibration
Termination
Characteristic
115 mH max.
12 DP (module 2.11)
or coarser
8 DP (module 3.17)
ferrous metal gear
40 kHz typ.
Mil-Std 202F
Method 204D
18 AWG PVC-Insulated
Leads
31,75
[1.250]
3000 MIN
[120.00]
1/2-14 NPT
Test Condition Specifications
Parameter
Characteristic
Surface speed 25 m/s
[1000 in/s]
Gear
8 DP
(module 3.17)
Air gap
0,127 mm
[0.005 in]
Load
100 kOhm
resistance
Catalog
Listing
3070A
3070A35
Thread
Weight
Length (A)
45 mm [1.8 in] 294 g [10.5 oz]
88 mm [3.5 in] 322 g [11.5 oz]
24,05
[1.00]
A
BLIND END SHELL
POLE PIECE
2
www.honeywell.com/sensing