Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be
operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored
without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
+25℃
2.1 Maximum Rating
DC voltage
VDC
12
V
AC voltage
Vpp
10
V
2.2 Electrical Characteristics
Source impedance
Zs=50Ω
Load impedance
Z
L
=2kΩ//3pF
Item
Freq
min
Insertion attenuation
44.06MHz
10.0
Reference level
45.81MHz
4.4
42.23MHz
0.7
Relative attenuation
41.31MHz
25.0
39.81MHz
42.0
47.31MHz
40.0
35.06~39.81MHz
36.0
Sidelobe
47.31~55.06MHz
35.0
Reflected wave signal suppression
1.1 us … 6.0 us after main pulse
40.0
(test pulse 250 ns ,
carrier frequency 44.06 MHz)
Feedthrough signal suppression
1.2 us … 1.1 us after main pulse
45.0
(test pulse 250 ns ,
carrier frequency 44.06 MHz)
Group delay ripple
(p-p)
-
Temperature coefficient of frequency
Between any terminals
Between any terminals
T
A
=25℃
typ
12.0
5.9
2.2
35.0
55.0
51.0
42.0
40.0
52.0
max
14.0
7.4
3.7
-
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
dB
dB
55.0
50
-72
-
dB
ns
Ppm/k
2.3 Environmental Performance Characteristics
Item Test condition
Allowable change of absolute
Level at center frequency(dB)
High temperature test
< 1.0
2