Thermal Profile (Option #300)
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
1
∆T
= 145°C, 1°C/SEC
∆T
= 115°C, 0.3°C/SEC
TEMPERATURE – °C
∆T
= 100°C, 1.5°C/SEC
2
3
4
5
6
7
8
9
10
11
12
TIME – MINUTES
Figure 1. Maximum Solder Reflow Thermal Profile.
(Note: Use of non-chlorine activated fluxes is recommended.)
Regulatory Information
The HCPL-2300 has been
approved by the following
organizations:
UL
Recognized under UL 1577,
Component Recognition
Program, File E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
VDE
Approved according to VDE
0884/06.92 (Option 060 only)
Insulation and Safety Related Specifications
Parameter
Min. External Air Gap
(External Clearance)
Min. External Tracking Path
(External Creepage)
Min. Internal Plastic Gap
(Internal Clearance)
Symbol
L(IO1)
L(IO2)
Value Units
7.1
7.4
0.08
mm
mm
mm
Conditions
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance path along body
Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity
DIN IEC 112/VDE 0303 PART 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
CTI
200
IIIa
Volts
Option 300 – surface mount classification is Class A in accordance with CECC 00802.
1-291